WL100
Manual Page 53 Revision: 1‐14‐2019
4.
Hot Water or Steam Coming out of both the Faucet and Vent Hole
Possible Reason
Solution
Improper Tubing attachment
from the Hot Tank to faucet or
vice versa.
Check that the Tubing is connected from Tank Outlets to correct
Faucet attachments. Connect Tubing to Outlets as needed.
5.
Hot Water Coming out of Faucet Vent Hole
Possible Reason
Solution
Too much water pressure.
Recommend 40 to 60 psi for
the
WL100 Water Treatment
System
to operate properly.
Check water pressure at the inlet bulkhead with a water pressure
gauge.
Additional method of verification is to turn off water to unit and
press the dispense button. Does the Solenoid open without water
pressure to the unit? Listen for Solenoid to activate, not to
mistaken for the button “click”.
Adjust water pressure to 40‐60 psi.
The correct input water
pressure is critical to the performance of the unit to allow
Solenoids to open.
Improper tubing attachment
from the tank to faucet or vice
versa.
Verify tubing is connected properly from tank outlets to correct
faucet attachments.
Hot Tank outlet hole is scaled
over.
Inspect and Descale Tank as needed.
See Hot Tank Descaling Instructions that are included further
below in this Troubleshooting Section.
Expansion chamber is not
sealed properly.
Replace the Hot Tank.