9
Step 7. Starting Up the Fusion 360 Filtration System
1. See Figure 5a above. Using the Phillips-head screwdriver, remove the screw as shown.
This will allow you to slide off the cabinet cowling from the rear. The top detachable cover
may also be removed by sliding it out towards the rear. See Figure 5b.
2. See Figure 6. This shows the location of the built-in Leak Stop device. It is installed in the
base of the cabinet and will contact any water that drains to the cabinet base. This device
will automatically shut off water from the cold water inlet, in the event an accidental leak in
the RO system is detected. This will protect your home from any accidental leakage that
could cause water damage.
It is very important to temporarily loosen the Leak Stop from its normal position any time
you are checking for leaks (such as on start-up) or changing cartridges. This may be done
by loosening the two mounting screws and gently raising the device from its normal
position. This will prevent accidental water contact with the device. It cannot be reset if it
gets wet and activates – it will require replacement to resume service, should this occur.
Sediment cartridge (AIP12EZ)
Auto shut-off valve
Carbon cartridge (AIC12EZ)
Membrane housing
Post carbon (AIC10EZ)
Storage tank valve
Leak Stop device
Figure 6.
3.
See Figure 6. Locate the membrane housing, mounted horizontally on the system’s
mounting bracket, next to the filter cartridges. Gently pull the membrane housing out of its
mounting brackets. Disconnect the ¼” tube attached to the membrane housing end cap.
Unscrew the end cap from the membrane housing. (Make sure your hands are washed
before proceeding further.) Remove the membrane element from its packaging. Insert the
membrane element into the housing, o-ring spigot first. Gently push until the membrane
seats snugly inside the housing. Re-install housing cap and poly tube connections. Gently
push the membrane housing back in its mounting brackets.
4. For model ROC101E (equipped with the booster pump), plug the wall adapter into a
standard 120V/60 Hz wall socket. The booster pump will not start at this time.