11
5. Grasp with the top cartridge (AIP12 - see figure 12) and gently pull out of its mounting clips.
Repeat with the AIC12 and AIC10 cartridges. Disconnect each from its tubing connections
(note blue C-clips must be removed first) and replace with the replacement cartridge. Make
sure each tube is reconnected correctly and the tubing is fully inserted and secured into
each fitting, with C-clips reinstalled.
6. Replace each cartridge back into its mounting clips by gently pushing them into place.
7. Turn the raw water saddle valve ON. Open the faucet and allow the system to run for two
minutes to flush. Check for leaks. Reassemble the detachable lid and cabinet cowling and
push the cabinet back in place. You may now resume normal use of the system.
Changing your RO Membrane Element
Membrane elements require changing much less frequently than the filter cartridges and only
when failure is indicated. This should be done when the water production rate begins to noticeably
fall or TDS readings in the product water begin to rise.
1. See Figure 5a above. Using the Phillips-head screwdriver, remove the cabinet cowling
screw as shown. This will allow you to slide off the cabinet cowling from the rear. The top
detachable cover may also be removed by sliding it out towards the rear. See Figure 5b.
2. Close the cold water supply saddle valve. Close the storage tank valve. Open the faucet
until the flow of water stops, and then close.
3. See Figure 6. Gently pull the membrane housing out of its mounting clips. Remove safety
clips from push-on fittings. Disconnect the ¼” tubes attached to the membrane housing.
Unscrew the end cap from the membrane housing.
4. If the old membrane element does not pull out easily by hand, use a needle nose pair of
pliers to gently pull and slightly rotate the element by the product tube until it slides out of
the housing. Use warm water, a mild soap solution and a bottlebrush to clean the interior
of the housing before installing the new element.
5. Wash hands and remove the new membrane element from its wrapping. Insert the
membrane element into the housing, o-ring spigot first. Gently push until the membrane
seats snugly inside the housing. Re-install housing cap and poly tubes, taking care that the
tubes are fully inserted into the fittings. Gently push the membrane housing back into its
mounting clips.
6. Turn the raw water saddle valve ON. Open the faucet and allow the system to run for two
minutes to flush. Check for leaks. Reassemble the detachable lid and cabinet cowling and
push the cabinet back in place. You may now resume normal use of the system.
Your Warranty
Keep your bill of sale and your warranty certificate, included in this kit. This is needed to claim any
parts or repair service during the warranty period. Read the document completely for warranty
claim instructions.
!