background image

1.

Leg

2.

Ashtray

3.

Base

4.

Base Heat Shield

5.

Combustion Chamber Base Plate

6.

Fire Door

7.

Side Panels

8.

Inside Fire Door

9.

Door Latch

10.

Top Side of Top Baffle

11.

Back Panel

12.

Back Baffle

13.

Hob

14.

Spigot

15.

Hotplate

16.

Front Frame

17.

Back Sealing Plate

18.

Back Sealing Plate Gasket

19.

Door Catch

20.

Window Sealing Tape

21.

Window Glass

22.

Fire Fence

23.

Front Side Brick (2)

24.

Rear Side Brick (2)

25.

Bottom Bricks

26.

Lower Side of Top Baffle

27.

Air Baffle

28.

Inside Back Heat Shield

29.

Door Sealing Rope

30.

Outside Back Heat Shield

31.

Spacers

32.

Optional Pipe Shield

33.

Heat Shield Blanking Plate

34.

Tie Bolts

35.

Top Baffle Plate Gasket

36.

Back Panel Gasket

37.

Side Panel Gaskets

38.

Back Baffle Gasket

39.

Primary & Secondary Air Spigot

40.

Primary and Secondary Air Flap

41.

Cast Iron Spacer

42.

Connecting Rod

43.

Primary Air Control Lever

44.

Primary & Secondary Air Spigot 
Flange

LEPRECHAUN 90 O.S.A.

WOOD BURNING STOVE

EXPLODED VIEW

U.S. ENVIRONMENTAL PROTECTION AGENCY

Certified to Comply with July 1990

Particulate Emission Standards

Maximum Heat Output up to 33,000 BTU’s/hr

Heat Output Range 9,000 - 26,700 BTU’s/hr

7

44

Содержание LEPRECHAUN 90 O.S.A

Страница 1: ...at all times and should not be allowed to touch the hot working surfaces while in use or until the appliance has thoroughly cooled If this stove is not properly installed a house fire may result For y...

Страница 2: ...A REAR VENT REAR FLUE EXIT Fit back sealing plate Part no 17 over the top flue aperture in the hob Part no 13 Fit the flue spigot to part no 11 where part no 17 was making sure that part no 17 and par...

Страница 3: ...1 4 6mm thick covered with 1 8 3mm sheet metal is required to cover the area under the heater and to extend to at least 18 450mm at the front and 8 200mm to the sides and rear This will provide pro t...

Страница 4: ...ts between air vents and outside walls should be sealed to prevent ingress of mois ture l This stove is listed for Mobile home installa tion provided it is properly connected to an outside air supply...

Страница 5: ...ances may be reduced by the percentage reduction as stated in the wall shield manufacturer s instructions For clearance reduction systems using an air space between the combustible wall and the wall p...

Страница 6: ...ry The connector may pass through walls or partitions constructed of combustible material to a masonry chimney provided the connector system selected is installed in accordance with the proper clearan...

Страница 7: ...nside Back Heat Shield 29 Door Sealing Rope 30 Outside Back Heat Shield 31 Spacers 32 Optional Pipe Shield 33 Heat Shield Blanking Plate 34 Tie Bolts 35 Top Baffle Plate Gasket 36 Back Panel Gasket 37...

Страница 8: ...diameter as the chimney connector and having 1 25mm or more of insulation with a min 9 230mm air space between the outer wall of the chimney length and combustibles The inner end of the chimney lengt...

Страница 9: ...less than 2 50mm from the face of the fireplace See Section under Minimum Clearances to Combustibles Before the installation the entire fireplace system should be inspected for condition and code com...

Страница 10: ...your finger when the pipe is cool If you hear a dull echo the pipe may need cleaning Disassemble the chimney connector and clean the sections Replace corroded pipe sections The fit ting of a slip join...

Страница 11: ...clean itself when there is sufficient heat generated by burning fuel The Air Way system provides pre heated warm air which keeps the glass clean WARNING DO NOT OPERATE THE STOVE WITH BROKEN GLASS 2 H...

Страница 12: ...or hot embers or sparks from the chimney LEPRECHAUN 90 O S A MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS SIDE WALL TO STOVE 20 INCHES 510 mm BACK WALL TO CHIMNEY CONNECTOR 18 INCHES 460mm BACK WALL T...

Отзывы: