Waterford LEPRECHAUN 90 O.S.A Скачать руководство пользователя страница 11

PRIMARY AIR SETTINGS

MAXIMUM - Pull control lever (item 43) all the way
towards the front.
LOW (MIN) - Push the control lever (item 43) all the
way towards the back.

When inspecting a masonry chimney, start at the
cleanout door, normally found in the basement, at
the base of the chimney, or on the outside.  If your
chimney does not have a clean-out door it must be
inspected and cleaned by removing stove from
chimney.

IMPORTANT:  NEVER LEAVE THE STOVE 
UNATTENDED WHEN THE FIREDOOR IS IN THE
CRACKED OPEN POSITION.

UNDER  NO  CIRCUMSTANCES  SHOULD  A N Y
FLAMMABLE LIQUIDS, KEROSENE, GAS OIL
LINE, NAPHTHA, ENGINE OIL,  LIGHTER FLUID
OR  CHARCOAL -  STARTERS  BE  USED  TO
LIGHT OR “FRESHEN UP” THE FIRE.  NEVER
USE MANUFACTURED LOGS.  KEEP ALL SUCH
LIQUIDS WELL AWAY FROM STOVE WHILE IN
USE

DO NOT USE GRATE OR ELEVATE FIRE - BUILD
WOOD FIRE DIRECTLY ON HEARTH.

DO NOT BURN GARBAGE/RUBBISH IN THIS
UNIT.

FUNCTION  DIAGRAM  OF  LEPRECHAUN  90
O.S.A. WOOD BURNING STOVE

MAINTENANCE

WARNING:  DO NOT CLEAN STOVE WHEN HOT.

GLASS

1.

How to Clean:

The glass will clean itself when there is sufficient
heat generated by burning fuel.  The Air Way system
provides pre-heated warm air which keeps the glass
clean.

WARNING:  DO NOT OPERATE THE STOVE
WITH BROKEN GLASS.

2.

How to Replace:

(a)

Open the door (item 6) and remove the 4 
1/4” (6.4mm) counter sunk screws from the 
inside Fire Door (item 8) and lift it away.

(b)

Remove the broken glass and gasket, take 
the replacement glass and fit gasket.

NOTE: If the gasket is damaged, use a new gasket

DOOR ASSEMBLY

(c)

Replace the glass and fit the Inside Fire Door
(item 8).  Tighten the 4 fixing screws.

(d)

Close the door to make sure that it is sealing
properly against the Front Frame (item 16).

VITREOUS ENAMEL CLEANING

General cleaning must be carried out when the
stove is cool.

If this stove is finished in a high gloss vitreous 
enamel, to keep the enamel in the best condition
observe the following tips:

1.

Wipe over daily with a soapy damp cloth, 
followed by a polish with a clean dry duster.

2.

For stubborn deposits a soap impregnated 
pad can be carefully used on the vitreous 
enamel.

3.

DO NOT USE ABRASIVE PADS OR OVEN
CLEANSERS CONTAINING CITRIC ACID 
ON ENAMELLED SURFACES.  ENSURE 
THAT THE CLEANSER MANUFACTUR
ERS INSTRUCTIONS ARE ADHERED TO.

11

Содержание LEPRECHAUN 90 O.S.A

Страница 1: ...at all times and should not be allowed to touch the hot working surfaces while in use or until the appliance has thoroughly cooled If this stove is not properly installed a house fire may result For y...

Страница 2: ...A REAR VENT REAR FLUE EXIT Fit back sealing plate Part no 17 over the top flue aperture in the hob Part no 13 Fit the flue spigot to part no 11 where part no 17 was making sure that part no 17 and par...

Страница 3: ...1 4 6mm thick covered with 1 8 3mm sheet metal is required to cover the area under the heater and to extend to at least 18 450mm at the front and 8 200mm to the sides and rear This will provide pro t...

Страница 4: ...ts between air vents and outside walls should be sealed to prevent ingress of mois ture l This stove is listed for Mobile home installa tion provided it is properly connected to an outside air supply...

Страница 5: ...ances may be reduced by the percentage reduction as stated in the wall shield manufacturer s instructions For clearance reduction systems using an air space between the combustible wall and the wall p...

Страница 6: ...ry The connector may pass through walls or partitions constructed of combustible material to a masonry chimney provided the connector system selected is installed in accordance with the proper clearan...

Страница 7: ...nside Back Heat Shield 29 Door Sealing Rope 30 Outside Back Heat Shield 31 Spacers 32 Optional Pipe Shield 33 Heat Shield Blanking Plate 34 Tie Bolts 35 Top Baffle Plate Gasket 36 Back Panel Gasket 37...

Страница 8: ...diameter as the chimney connector and having 1 25mm or more of insulation with a min 9 230mm air space between the outer wall of the chimney length and combustibles The inner end of the chimney lengt...

Страница 9: ...less than 2 50mm from the face of the fireplace See Section under Minimum Clearances to Combustibles Before the installation the entire fireplace system should be inspected for condition and code com...

Страница 10: ...your finger when the pipe is cool If you hear a dull echo the pipe may need cleaning Disassemble the chimney connector and clean the sections Replace corroded pipe sections The fit ting of a slip join...

Страница 11: ...clean itself when there is sufficient heat generated by burning fuel The Air Way system provides pre heated warm air which keeps the glass clean WARNING DO NOT OPERATE THE STOVE WITH BROKEN GLASS 2 H...

Страница 12: ...or hot embers or sparks from the chimney LEPRECHAUN 90 O S A MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS SIDE WALL TO STOVE 20 INCHES 510 mm BACK WALL TO CHIMNEY CONNECTOR 18 INCHES 460mm BACK WALL T...

Отзывы: