Waterco INFINIUM ECO-V150 Скачать руководство пользователя страница 8

INFINIUM ∞ ECO-V150 

Variable Speed Pump

I pg 13

Programing

Introduction

The INFINIUM ECO V-150 uses a premium efficiency variable speed motor that provides 
tremendous program flexibility in terms of motor speed and time settings. The variable speed 
motor is intended to enable running at the lowest speeds needed to maintain a sanitary 
environment, which in turn minimizes energy consumption. Pool size, the presence of additional 
water features, chemicals used to maintain sanitary conditions, and environmental factors will 
impact optimal programming necessary to maximize energy conservation.

The integrated electronics interface controls the speed settings as well as the run durations. 
The INFINIUM ECO V-150 can run at speeds ranging between 600 and 3450 RPM and is rated 
for 208-230 Vrms at an input frequency of 60 Hz.

Navigation Overview

>

  +, - Increases/decreases selected value

>

  Pressing any key following a change accepts the current value displayed inside the setting

Note:

 The START button must be pressed for the INFINIUM ECO V-150 to operate. The START 

LED will illuminate after the button has been pressed indicating the INFINIUM ECO V-150 is 
capable of operating. Pressing the stop button will turn off the START LED and stop the motor 
if running

Maintenance

• 

Clean strainer basket regularly. Do NOT strike basket to clean. Inspect strainer cover 
gasket regularly and replace as necessary.

• 

Waterco pumps have self-lubricating motor bearings and shaft seals. No lubrication 
is necessary.

•  Keep motor clean. Insure air vents are free from obstruction to avoid damage. Do 

NOT use water to hose off motor.

•  Occasionally, shaft seals must be replaced, due to wear or damage. Replace with 

genuine Waterco seal assembly kit. 

Storage/Winterization

 

!

 

!

  WARNING – Separation Hazard.  Do not purge the system with compressed air. 

Purging the system with compressed air can cause components to explode, with risk 
of severe injury or death to anyone nearby. Use only a low pressure (below 5 PSI), 
high volume blower when air purging the pump, filter, or piping.

 

!

 

!

  ATTENTION – Allowing the pump to freeze will void the warranty.

 

!

 

!

  ATTENTION – Use ONLY propylene glycol as antifreeze in your pool/spa system. 

Propylene glycol is non- toxic and will not damage plastic system components; other 
anti-freezes are highly toxic and may damage plastic components in the system.

 

!

 

!

  WARNING – To avoid dangerous or fatal electrical shock hazard, turn OFF power 

to motor before draining pump. Failure to disconnect power may result in serious 
personal injury or death.

Storing Pump For Winterization

• 

Drain water level below all inlets to the pool.

• 

Drain all water from pump and piping when expecting freezing temperatures or when 
storing pump for a long time (see instructions below).

•  Remove drain plugs from bottom of strainer body, and remove strainer cover from 

strainer housing.

•  Disconnect pump from mounting pad, wiring system (after power has been turned 

OFF), and piping system.

•  Keep motor dry and covered during storage. To avoid condensation/corrosion 

problems, do NOT cover or wrap pump with plastic film or bags.

Figure 1 : V-Green 165 User Interface Button Descriptions

Содержание INFINIUM ECO-V150

Страница 1: ...p INSTALLATION AND USER S GUIDE NOTICE TO INSTALLER THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE INSTALLATION OPERATION AND SAFE USE OF THIS PRODUCT ONCE THE PRODUCT HAS BEEN INSTALLED THIS MANUAL MUST BE GIVEN TO THE OWNER OPERATOR OF THIS EQUIPMENT THIS EQUIPMENT MUST BE INSTALLED AND SERVICED BY A QUALIFIED TECHNICIAN IMPROPER INSTALLATION CAN CREATE ELECTRICAL HAZARDS WHICH COULD RESUL...

Страница 2: ...Push the reset button Power should be restored If the GFCI fails to operate in this manner the GFCI is defective If the GFCI interrupts power to the pump without the test button being pushed a ground current is flowing indicating the possibility of an electric shock Do not use this pump Disconnect the pump and have the problem corrected by a qualified service representative before using CAUTION Th...

Страница 3: ... Spas and Hot Tubs or A properly designed and tested suction limiting vent system or An automatic pump shut off system WARNING Suction Entrapment Hazard Suction in suction outlets and or suction outlet covers which are damaged broken cracked missing or unsecured cause severe injury and or death due to the following entrapment hazards Hair Entrapment Hair can become entangled in suction outlet cove...

Страница 4: ...y TEFC motor and highly engineered hydraulics make this rugged and tested design perfect for any pool spa water feature or fountain All pumps from Waterco incorporate innovative hydraulic engineering that has been refined for over 40 years Compact rugged and easy to maintain the Infinium Eco V pump will deliver years of reliable service Pump Controller Features Simple user interface Motor design r...

Страница 5: ...ter velocity It is recommended that a minimum length of piping equivalent to 10 pipe diameters be used between the pump suction inlet and any plumbing fittings Plumbing The INFINIUM ECO V 150 comes equipped with external and internal threads External threads are designed to be used with the supplied union adapter only and seals with an O ring No thread sealant is used when using the union connecto...

Страница 6: ...supply to the motor permanently ground the motor using the ground screw located on the inside rear of the controller interface see figure 3 7 Use the correct wire size and type specified by the current National Electrical Code Be sure the ground wire is connected to an electrical service ground and never ground to a gas line 8 Prior to connecting the power supply to the motor Bond the motor to the...

Страница 7: ...ner cover by turning the lid Counter Clockwise Fill strainer housing with water up to the suction pipe level If water source is higher than the pump pump will prime itself when suction and outlet valves are opened Always verify the strainer housing is full of water If water source is lower than the pump the pump must be filled Clean and lubricate strainer cover O ring with Silicone based O ring Lu...

Страница 8: ...t seals No lubrication is necessary Keep motor clean Insure air vents are free from obstruction to avoid damage Do NOT use water to hose off motor Occasionally shaft seals must be replaced due to wear or damage Replace with genuine Waterco seal assembly kit Storage Winterization WARNING Separation Hazard Do not purge the system with compressed air Purging the system with compressed air can cause c...

Страница 9: ...g buttons referred to in section 3 could result in the motor starting Failure to recognize this could result in personal injury or damage to equipment Button Duration In Hours Speed In RPM STEP 1 4 3100 STEP 2 4 2600 STEP 3 8 1600 OVERRIDE 2 3450 Quick Start Instructions Quick Start Guide Using the factory default schedule The following table describes the factory default settings for DURATION and...

Страница 10: ...des not to save the settings pressing the STOP key will revert back to the previously stored setting 5 Press STEP 2 STEP 3 or OVERRIDE key Repeat steps 1 4 to program the corresponding DURATION and SPEED for each button 6 Press START to run the INFINIUM ECO V 150 based on the programmed 24 hour schedule 7 Pressing the STOP button will stop the INFINIUM ECO V 150 Figure 2 INFINIUM ECO V 150 Overvie...

Страница 11: ...50 then starts running in STEP 1 at the programmed DURATION and SPEED The ACTIVE LED for STEP 1 will turn ON The DURATION and SPEED setting LEDs along with the respective bar graph LED will blink back and forth every three 3 seconds User Interface Key Pad Overview 1 STEP 1 Set Schedule DURATION and SPEED 2 STEP 2 Set Schedule DURATION and SPEED 3 STEP 3 Set Schedule DURATION and SPEED 4 OVERRIDE S...

Страница 12: ... arrows are pressed NOTE When the OVERRIDE duration ends the INFINIUM ECO V 150 resumes the 24 hour schedule at the point in the currently programmed 24 hour schedule where it normally would be running at that time The OVER RIDE duration will not affect the start or stop times of the 24 hour schedule For example if OVERRIDE runs during a period overlapping with a later part of STEP 1 and an early ...

Страница 13: ...NIUM ECO V 150 when being controlled by a serial or digital input The user can press the STOP button while the INFINIUM ECO V 150 is running and the INFINIUM ECO V 150 will stop and stay off for four 4 minutes Once this time has elapsed the INFINIUM ECO V 150 will return to normal operation and accept an input from digital or serial input source Refer to section 9 for additional details on digital...

Страница 14: ...damaging the equipment if contact is made Power should be turned off when accessing this area Freeze Protection In the event that the outside air temperature drops below a set threshold the INFINIUM ECO V 150 will automatically turn on assuming the START button has been pressed and circulate the pool water The Freeze Protection will run according to the following conditions utilizing the factory d...

Страница 15: ...50 does not restart automatically following the FAULT cycle ac power to the INFINIUM ECO V 150 and wait five 5 minutes If this does not correct the situation please contact Customer Service at 706 793 7291 The INFINIUM ECO V 150 reads the FAULT status and provides feedback to the user via the FAULT LED The INFINIUM ECO V 150 will illuminate the FAULT LED when a FAULT is present The INFINIUM ECO V ...

Страница 16: ...lid gasket is in place Check water level to be sure skimmer is not drawing air Pump will not prime Not enough water Be sure the suction lines pump strainer and pump volute are full of water Be sure valve on suction line is working and open some systems do not have valves Check water level to make sure water is available through skimmer Clean pump strainer pot Replace gasket REDUCED CAPACITY AND OR...

Страница 17: ...V AC 20 or 9 30V DC 12 24V DC 20 Auxiliary Load Terminals N A Maximum Continuous Load 1 65 THP Total Horse Power Speed Range 600 3450 RPM Environmental Rating NEMA Type 3R Agency Approval R C XDNW2 E302804 R C XDNW2 E302804 Ambient Conditions Storage Operating Humidity 40 C to 85 C 40 F to 185 F 0 C to 50 C 32 F to 122 F Relative 0 to 95 non condensing Pump Performance Curves SPECIFICATIONS ...