INFINIUM ∞ ECO-V150 

Variable Speed Pump

I pg 27

Switch #

Function

1

Power output on/off

2

Not Used

Not Used

4

Not Used

5

Not Used

Table 5: DIP Switch Functions

Figure 8: DIP Switches

!

 

WARNING

While the FAULT LED is illuminated the motor will not run, upon clearing the fault, the motor 
may automatically resume running depending on where in the schedule the FAULT occurred. 
This may cause personal injury or damage to the equipment.

!

 

WARNING

Diagnosing certain symptoms may require close interaction with, or in close proximity to, 
components that are energized with electricity. Contact with electricity can cause death, 
personal injury, or property damage. When trouble shooting the INFINIUM ECO V-150 
diagnostics involving electricity should be cared for by a licensed professional.

DIP Switches

The DIP switches can be used to configure different settings for the INFINIUM ECO V-150. Each 
DIP switch and their corresponding function is defined in Table 5.

Care and Maintenance

The INFINIUM ECO V-150 is both reliable and robust in harsh environments. However, this 
product does contain electronics that are cooled by a fan mounted to the INFINIUM ECO V-150 
In order to ensure optimum reliability of this product, it is recommended to clean the fan inlet on 
the back of the INFINIUM ECO V-150 once a month. It is also important to keep this area free 
of large debris such as leaves, branches, mulch, plastic bags, etc.

The paragraphs below illustrate the possible faults that can occur with the INFINIUM ECO 
V-150 If the INFINIUM ECO V-150 does not restart automatically following the FAULT, cycle 
ac power to the INFINIUM ECO V-150 and wait five (5) minutes. If this does not correct the 
situation, please contact Customer Service at 706-793-7291.

The INFINIUM ECO V-150 reads the FAULT status and provides feedback to the user via the 
FAULT LED. The INFINIUM ECO V-150 will illuminate the FAULT LED when a FAULT is present. 
The INFINIUM ECO V-150 will stop and remain OFF when the FAULT is present. Once the 
FAULT is cleared, if the INFINIUM ECO V-150 was previously running, it will automatically 
resume running the normal schedule.

Below is the behavior of the FAULT LED when a FAULT is detected:

1.  When a FAULT is present, and the motor is not running, only the FAULT LED and power 

LED will illuminate.

2.  When a FAULT is present, and the motor is running, then the FAULT LED will illuminate. 

During the FAULT condition, the bar graph LEDs on the interface will turn OFF. However, 
the power LED, start LED & active STEP LED will remain illuminated. 3. When a FAULT is 
present and the FAULT LED is illuminated, only the STOP key will function. The remaining 
buttons become disabled.

4.  When the FAULT LED is continuously ON (i.e. not blinking), a FAULT is present in the 

controller. When the FAULT LED is blinking every one (1) second, a FAULT is present in the 
user interface.

5.  When the FAULT has cleared, the FAULT LED will turn OFF.

6.  Once the FAULT is cleared, if the INFINIUM ECO V-150 was previously running, it will 

automatically resume running the normal schedule.

Please see page 25 for troubleshooting issues and their resolutions.

FAULT Status

Figure 7: System Level Control Wiring Diagram

System Level Control

Load

Load

Load

Load

Line

Line

Line

Line

Relay 1

Relay 2 Relay 3

Relay 4

Содержание INFINIUM ECO-V150

Страница 1: ...p INSTALLATION AND USER S GUIDE NOTICE TO INSTALLER THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE INSTALLATION OPERATION AND SAFE USE OF THIS PRODUCT ONCE THE PRODUCT HAS BEEN INSTALLED THIS MANUAL MUST BE GIVEN TO THE OWNER OPERATOR OF THIS EQUIPMENT THIS EQUIPMENT MUST BE INSTALLED AND SERVICED BY A QUALIFIED TECHNICIAN IMPROPER INSTALLATION CAN CREATE ELECTRICAL HAZARDS WHICH COULD RESUL...

Страница 2: ...Push the reset button Power should be restored If the GFCI fails to operate in this manner the GFCI is defective If the GFCI interrupts power to the pump without the test button being pushed a ground current is flowing indicating the possibility of an electric shock Do not use this pump Disconnect the pump and have the problem corrected by a qualified service representative before using CAUTION Th...

Страница 3: ... Spas and Hot Tubs or A properly designed and tested suction limiting vent system or An automatic pump shut off system WARNING Suction Entrapment Hazard Suction in suction outlets and or suction outlet covers which are damaged broken cracked missing or unsecured cause severe injury and or death due to the following entrapment hazards Hair Entrapment Hair can become entangled in suction outlet cove...

Страница 4: ...y TEFC motor and highly engineered hydraulics make this rugged and tested design perfect for any pool spa water feature or fountain All pumps from Waterco incorporate innovative hydraulic engineering that has been refined for over 40 years Compact rugged and easy to maintain the Infinium Eco V pump will deliver years of reliable service Pump Controller Features Simple user interface Motor design r...

Страница 5: ...ter velocity It is recommended that a minimum length of piping equivalent to 10 pipe diameters be used between the pump suction inlet and any plumbing fittings Plumbing The INFINIUM ECO V 150 comes equipped with external and internal threads External threads are designed to be used with the supplied union adapter only and seals with an O ring No thread sealant is used when using the union connecto...

Страница 6: ...supply to the motor permanently ground the motor using the ground screw located on the inside rear of the controller interface see figure 3 7 Use the correct wire size and type specified by the current National Electrical Code Be sure the ground wire is connected to an electrical service ground and never ground to a gas line 8 Prior to connecting the power supply to the motor Bond the motor to the...

Страница 7: ...ner cover by turning the lid Counter Clockwise Fill strainer housing with water up to the suction pipe level If water source is higher than the pump pump will prime itself when suction and outlet valves are opened Always verify the strainer housing is full of water If water source is lower than the pump the pump must be filled Clean and lubricate strainer cover O ring with Silicone based O ring Lu...

Страница 8: ...t seals No lubrication is necessary Keep motor clean Insure air vents are free from obstruction to avoid damage Do NOT use water to hose off motor Occasionally shaft seals must be replaced due to wear or damage Replace with genuine Waterco seal assembly kit Storage Winterization WARNING Separation Hazard Do not purge the system with compressed air Purging the system with compressed air can cause c...

Страница 9: ...g buttons referred to in section 3 could result in the motor starting Failure to recognize this could result in personal injury or damage to equipment Button Duration In Hours Speed In RPM STEP 1 4 3100 STEP 2 4 2600 STEP 3 8 1600 OVERRIDE 2 3450 Quick Start Instructions Quick Start Guide Using the factory default schedule The following table describes the factory default settings for DURATION and...

Страница 10: ...des not to save the settings pressing the STOP key will revert back to the previously stored setting 5 Press STEP 2 STEP 3 or OVERRIDE key Repeat steps 1 4 to program the corresponding DURATION and SPEED for each button 6 Press START to run the INFINIUM ECO V 150 based on the programmed 24 hour schedule 7 Pressing the STOP button will stop the INFINIUM ECO V 150 Figure 2 INFINIUM ECO V 150 Overvie...

Страница 11: ...50 then starts running in STEP 1 at the programmed DURATION and SPEED The ACTIVE LED for STEP 1 will turn ON The DURATION and SPEED setting LEDs along with the respective bar graph LED will blink back and forth every three 3 seconds User Interface Key Pad Overview 1 STEP 1 Set Schedule DURATION and SPEED 2 STEP 2 Set Schedule DURATION and SPEED 3 STEP 3 Set Schedule DURATION and SPEED 4 OVERRIDE S...

Страница 12: ... arrows are pressed NOTE When the OVERRIDE duration ends the INFINIUM ECO V 150 resumes the 24 hour schedule at the point in the currently programmed 24 hour schedule where it normally would be running at that time The OVER RIDE duration will not affect the start or stop times of the 24 hour schedule For example if OVERRIDE runs during a period overlapping with a later part of STEP 1 and an early ...

Страница 13: ...NIUM ECO V 150 when being controlled by a serial or digital input The user can press the STOP button while the INFINIUM ECO V 150 is running and the INFINIUM ECO V 150 will stop and stay off for four 4 minutes Once this time has elapsed the INFINIUM ECO V 150 will return to normal operation and accept an input from digital or serial input source Refer to section 9 for additional details on digital...

Страница 14: ...damaging the equipment if contact is made Power should be turned off when accessing this area Freeze Protection In the event that the outside air temperature drops below a set threshold the INFINIUM ECO V 150 will automatically turn on assuming the START button has been pressed and circulate the pool water The Freeze Protection will run according to the following conditions utilizing the factory d...

Страница 15: ...50 does not restart automatically following the FAULT cycle ac power to the INFINIUM ECO V 150 and wait five 5 minutes If this does not correct the situation please contact Customer Service at 706 793 7291 The INFINIUM ECO V 150 reads the FAULT status and provides feedback to the user via the FAULT LED The INFINIUM ECO V 150 will illuminate the FAULT LED when a FAULT is present The INFINIUM ECO V ...

Страница 16: ...lid gasket is in place Check water level to be sure skimmer is not drawing air Pump will not prime Not enough water Be sure the suction lines pump strainer and pump volute are full of water Be sure valve on suction line is working and open some systems do not have valves Check water level to make sure water is available through skimmer Clean pump strainer pot Replace gasket REDUCED CAPACITY AND OR...

Страница 17: ...V AC 20 or 9 30V DC 12 24V DC 20 Auxiliary Load Terminals N A Maximum Continuous Load 1 65 THP Total Horse Power Speed Range 600 3450 RPM Environmental Rating NEMA Type 3R Agency Approval R C XDNW2 E302804 R C XDNW2 E302804 Ambient Conditions Storage Operating Humidity 40 C to 85 C 40 F to 185 F 0 C to 50 C 32 F to 122 F Relative 0 to 95 non condensing Pump Performance Curves SPECIFICATIONS ...

Отзывы: