Waterco INFINIUM ECO-V150 Скачать руководство пользователя страница 3

INFINIUM ∞ ECO-V150 

Variable Speed Pump

I pg 03

• 

PUMPS IMPROPERLY SIZED OR INSTALLED OR USED IN APPLICATIONS OTHER THAN 
FOR WHICH THE PUMP WAS INTENDED CAN RESULT IN SEVERE PERSONAL INJURY 
OR DEATH. THESE RISKS MAY INCLUDE BUT NOT BE LIMITED TO ELECTRIC SHOCK, 
FIRE, FLOODING, SUCTION ENTRAPMENT OR SEVERE INJURY OR PROPERTY 
DAMAGE CAUSED BY A STRUCTURAL FAILURE OF THE PUMP OR OTHER SYSTEM 
COMPONENT.

• 

!

 

WARNING

 

– To reduce the risk of Entrapment Hazards:

•  When outlets are small enough to be blocked by a person, a minimum of two 

functioning suction outlets per pump must be installed. Suction outlets in the same 
plane (i.e. floor or wall), must be installed a minimum of three feet (3’) [0.91 meter] 
apart, as measured from near point to near point.

•  Dual suction fittings shall be placed in such locations and distances to avoid “dual 

blockage” by a user.

•  Dual suction fittings shall not be located on seating areas or on the backrest for such 

seating areas.

•  The maximum system flow rate shall not exceed the values shown in the “Pipe Sizing 

Chart” found at the bottom of page 5 of this manual.

•  Never use pool or spa if any suction outlet component is damaged, broken, cracked, 

missing, or not securely attached.

•  Replace damaged, broken, cracked, missing, or not securely attached suction outlet 

components immediately.

•  In addition to two or more suction outlets per pump installed in accordance with latest 

IAF (formerly NSPI) standards and CPSC guidelines, follow all national, state, and local 
codes applicable.

•  Installation of a vacuum release or vent system, which relieves entrapping suction, is 

recommended.

The Virginia Graeme Baker (VGB) Pool and Spa Safety Act creates new requirements for 
owners and operators of commercial swimming pools and spas. Commercial pools or 
spas constructed on or after December 19, 2008, shall utilize:

•  A multiple main drain system without isolation capability with suction outlet covers that 

meet ASME/ANSI A112.19.8a Suction Fittings for Use in Swimming Pools, Wading 
Pools, Spas, and Hot Tubs and either:

•  A safety vacuum release system (SVRS) meeting ASME/ANSI A112.19.17 Manufactured 

Safety Vacuum Release systems (SVRS) for  Residential  and  Commercial  Swimming  
Pool,  Spa,  Hot  Tub, and Wading Pool Suction Systems and/or ASTM F2387 
Standard Specification  for  Manufactured  Safety  Vacuum  Release  Systems (SVRS) 
for Swimming pools, Spas and Hot Tubs or

•  A properly designed and tested suction-limiting vent system or

•  An automatic pump shut-off system.

• 

!

 

WARNING

 

– Suction Entrapment Hazard.

 Suction in suction outlets and/or suction 

outlet covers, which are damaged, broken, cracked, missing, or unsecured cause severe 
injury and/or death due to the following entrapment hazards:

• 

Hair Entrapment 

- Hair can become entangled in suction outlet cover.

• L

imb Entrapment 

- A limb inserted into an opening of a suction outlet sump or suction 

outlet cover that is damaged, broken, cracked, missing, or not securely attached can 
result in a mechanical bind or swelling of the limb.

• 

Body Suction Entrapment 

- A pressure applied to a large portion of the body or limbs 

can result in an entrapment. 

• 

Evisceration/ Disembowelment 

- A negative pressure applied directly to the intestines 

through an unprotected suction outlet sump or suction outlet cover which is damaged, 
broken, cracked, missing, or unsecured can result in evisceration/disembowelment.

• 

Mechanical Entrapment 

- There is potential for jewelry, swimsuits, hair decorations, 

fingers, toes, or knuckles to be caught in an opening of a suction outlet cover resulting 
in mechanical entrapment.

General Warnings

• 

Never open the inside of the drive motor enclosure. There is a capacitor bank that holds a 
230 VAC charge even when there is no power to the unit.

• 

The pump is not submersible.

• 

The pump is capable of high flow rates; use caution when installing and programming to 
limit pumps performance potential with old or questionable equipment.

• 

Code requirements for the electrical connection differ from state to state. Install equipment 
in accordance with the current National Electrical Code and all applicable local codes and 
ordinances.

•  Before servicing the pump; switch OFF power to the pump by disconnecting the main 

circuit to the pump.

• 

This appliance is not intended for use by persons (including children) of reduced physical, 
sensory or mental capabilities, or lack of experience and knowledge, unless they have 
been given supervision or instruction concerning the use of the appliance by a person 
responsible for their safety.

NOTE:

•  ALL SUCTION PLUMBING MUST BE INSTALLED IN ACCORDANCE WITH THE LATEST 

NATIONAL AND LOCAL CODES, STANDARDS AND GUIDELINES.

• 

THIS PUMP PRODUCES HIGH LEVELS OF SUCTION AND CREATES A STRONG VACUUM 
AT THE MAIN DRAIN AT THE BOTTOM OF THE BODY OF WATER. THIS SUCTION IS SO 
STRONG THAT IT CAN TRAP ADULTS OR CHILDREN UNDER WATER IF THEY COME IN 
CLOSE PROXIMITY TO A DRAIN OR A LOOSE OR BROKEN DRAIN COVER OR GRATE.

Содержание INFINIUM ECO-V150

Страница 1: ...p INSTALLATION AND USER S GUIDE NOTICE TO INSTALLER THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE INSTALLATION OPERATION AND SAFE USE OF THIS PRODUCT ONCE THE PRODUCT HAS BEEN INSTALLED THIS MANUAL MUST BE GIVEN TO THE OWNER OPERATOR OF THIS EQUIPMENT THIS EQUIPMENT MUST BE INSTALLED AND SERVICED BY A QUALIFIED TECHNICIAN IMPROPER INSTALLATION CAN CREATE ELECTRICAL HAZARDS WHICH COULD RESUL...

Страница 2: ...Push the reset button Power should be restored If the GFCI fails to operate in this manner the GFCI is defective If the GFCI interrupts power to the pump without the test button being pushed a ground current is flowing indicating the possibility of an electric shock Do not use this pump Disconnect the pump and have the problem corrected by a qualified service representative before using CAUTION Th...

Страница 3: ... Spas and Hot Tubs or A properly designed and tested suction limiting vent system or An automatic pump shut off system WARNING Suction Entrapment Hazard Suction in suction outlets and or suction outlet covers which are damaged broken cracked missing or unsecured cause severe injury and or death due to the following entrapment hazards Hair Entrapment Hair can become entangled in suction outlet cove...

Страница 4: ...y TEFC motor and highly engineered hydraulics make this rugged and tested design perfect for any pool spa water feature or fountain All pumps from Waterco incorporate innovative hydraulic engineering that has been refined for over 40 years Compact rugged and easy to maintain the Infinium Eco V pump will deliver years of reliable service Pump Controller Features Simple user interface Motor design r...

Страница 5: ...ter velocity It is recommended that a minimum length of piping equivalent to 10 pipe diameters be used between the pump suction inlet and any plumbing fittings Plumbing The INFINIUM ECO V 150 comes equipped with external and internal threads External threads are designed to be used with the supplied union adapter only and seals with an O ring No thread sealant is used when using the union connecto...

Страница 6: ...supply to the motor permanently ground the motor using the ground screw located on the inside rear of the controller interface see figure 3 7 Use the correct wire size and type specified by the current National Electrical Code Be sure the ground wire is connected to an electrical service ground and never ground to a gas line 8 Prior to connecting the power supply to the motor Bond the motor to the...

Страница 7: ...ner cover by turning the lid Counter Clockwise Fill strainer housing with water up to the suction pipe level If water source is higher than the pump pump will prime itself when suction and outlet valves are opened Always verify the strainer housing is full of water If water source is lower than the pump the pump must be filled Clean and lubricate strainer cover O ring with Silicone based O ring Lu...

Страница 8: ...t seals No lubrication is necessary Keep motor clean Insure air vents are free from obstruction to avoid damage Do NOT use water to hose off motor Occasionally shaft seals must be replaced due to wear or damage Replace with genuine Waterco seal assembly kit Storage Winterization WARNING Separation Hazard Do not purge the system with compressed air Purging the system with compressed air can cause c...

Страница 9: ...g buttons referred to in section 3 could result in the motor starting Failure to recognize this could result in personal injury or damage to equipment Button Duration In Hours Speed In RPM STEP 1 4 3100 STEP 2 4 2600 STEP 3 8 1600 OVERRIDE 2 3450 Quick Start Instructions Quick Start Guide Using the factory default schedule The following table describes the factory default settings for DURATION and...

Страница 10: ...des not to save the settings pressing the STOP key will revert back to the previously stored setting 5 Press STEP 2 STEP 3 or OVERRIDE key Repeat steps 1 4 to program the corresponding DURATION and SPEED for each button 6 Press START to run the INFINIUM ECO V 150 based on the programmed 24 hour schedule 7 Pressing the STOP button will stop the INFINIUM ECO V 150 Figure 2 INFINIUM ECO V 150 Overvie...

Страница 11: ...50 then starts running in STEP 1 at the programmed DURATION and SPEED The ACTIVE LED for STEP 1 will turn ON The DURATION and SPEED setting LEDs along with the respective bar graph LED will blink back and forth every three 3 seconds User Interface Key Pad Overview 1 STEP 1 Set Schedule DURATION and SPEED 2 STEP 2 Set Schedule DURATION and SPEED 3 STEP 3 Set Schedule DURATION and SPEED 4 OVERRIDE S...

Страница 12: ... arrows are pressed NOTE When the OVERRIDE duration ends the INFINIUM ECO V 150 resumes the 24 hour schedule at the point in the currently programmed 24 hour schedule where it normally would be running at that time The OVER RIDE duration will not affect the start or stop times of the 24 hour schedule For example if OVERRIDE runs during a period overlapping with a later part of STEP 1 and an early ...

Страница 13: ...NIUM ECO V 150 when being controlled by a serial or digital input The user can press the STOP button while the INFINIUM ECO V 150 is running and the INFINIUM ECO V 150 will stop and stay off for four 4 minutes Once this time has elapsed the INFINIUM ECO V 150 will return to normal operation and accept an input from digital or serial input source Refer to section 9 for additional details on digital...

Страница 14: ...damaging the equipment if contact is made Power should be turned off when accessing this area Freeze Protection In the event that the outside air temperature drops below a set threshold the INFINIUM ECO V 150 will automatically turn on assuming the START button has been pressed and circulate the pool water The Freeze Protection will run according to the following conditions utilizing the factory d...

Страница 15: ...50 does not restart automatically following the FAULT cycle ac power to the INFINIUM ECO V 150 and wait five 5 minutes If this does not correct the situation please contact Customer Service at 706 793 7291 The INFINIUM ECO V 150 reads the FAULT status and provides feedback to the user via the FAULT LED The INFINIUM ECO V 150 will illuminate the FAULT LED when a FAULT is present The INFINIUM ECO V ...

Страница 16: ...lid gasket is in place Check water level to be sure skimmer is not drawing air Pump will not prime Not enough water Be sure the suction lines pump strainer and pump volute are full of water Be sure valve on suction line is working and open some systems do not have valves Check water level to make sure water is available through skimmer Clean pump strainer pot Replace gasket REDUCED CAPACITY AND OR...

Страница 17: ...V AC 20 or 9 30V DC 12 24V DC 20 Auxiliary Load Terminals N A Maximum Continuous Load 1 65 THP Total Horse Power Speed Range 600 3450 RPM Environmental Rating NEMA Type 3R Agency Approval R C XDNW2 E302804 R C XDNW2 E302804 Ambient Conditions Storage Operating Humidity 40 C to 85 C 40 F to 185 F 0 C to 50 C 32 F to 122 F Relative 0 to 95 non condensing Pump Performance Curves SPECIFICATIONS ...

Отзывы: