Source Water Supply 

Community/Private 

Non-Chlorinated – or chlorinated as long as the carbon filter is in place 
and replaced every 6 months.  Chlorine will damage membranes if not 
removed properly. 

System Pressure 

40 psi minimum - 90 psi maximum 

Temperature 

4º-38º C (40º-100º F) 

Maximum Supply TDS Level 

1500 ppm (mg/L) 

Turbidity 

<1.0 Net Turbidity (NTU) 

 

Chemical Parameters 

Hardness (CaCO3) 

<175 mg/L (<10 gpg)* 

Iron (Fe) 

<0.1 mg/L 

Manganese (Mn) 

<0.05 mg/L 

Hydrogen Sulfide (H2S) 

0.00 mg/L 

Chlorine (CL2) 

0.00 mg/L 

pH 

4 to 11  

*Note that system may operate with higher hardness levels, but the membrane life will be reduced.  Use of a 
water softener for hard water supplies will increase membrane life and efficiency. 

Warnings 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  Only use this system on potable water supplies.  Do not use this system where the 

water is microbiologically unsafe or of unknown quality. 

  Never use hot water or allow the unit to freeze. 

  Incorrect installation or operation will void the warranty. 

  Excessive incoming water pressure can cause leaks, flooding and property damage.  It 

is highly recommended to monitor your home’s incoming water pressure over a period 
of 24 hours to determine if a pressure regulator is required. 

  Manufacturer assumes no responsibility for damages incurred through improper 

installation or use of these products. 

  Ensure that all tubing and fittings used for RO product water are poly material, and not 

copper.   Due to RO product water being very pure, it can leach the minerals from 
copper tubing which will cause a metallic taste in the water or ice and cause the copper 
tubing to develop pinhole leaks over time. 

 

 

 

Содержание AAA-RO200W

Страница 1: ...ywhere com 760 727 1652 sales wateranywhere com Manual for Installation Operation and Maintenance of 5 Stage Point of Use Reverse Osmosis Drinking Water System Document ID AAARO200W Revision 05 13 20...

Страница 2: ...e 4 2 Reverse Osmosis Membranes Replace every 12 months The fourth stage is the reverse osmosis membrane which is the heart of the RO system To achieve a higher product water flow the water stream is...

Страница 3: ...ousings onto System Manifold 5 Prepare Tubing 6 Quick Connect Fittings and Tubing Connections 6 Installation Steps Step 1 Drill a Hole into the Sink for the Faucet 7 Step 2 Faucet Installation 8 Step...

Страница 4: ...water softener for hard water supplies will increase membrane life and efficiency Warnings Only use this system on potable water supplies Do not use this system where the water is microbiologically u...

Страница 5: ...housing D Housing with RO Membrane 2 in parallel E Four way Valve F In Line Cartridge with Activated Carbon G Flow Restrictor H Tank Valve I Tank J Faucet 1 Clean Water Outlets 2 Pollutants Outlets 3...

Страница 6: ...er hazards Determine the location of the cold water feed line to use for the system supply Notice Accidentally hooking up the system to the hot water supply line will permanently damage the membrane s...

Страница 7: ...s and Tubing Connections To ensure a secure seal using quick connect fittings Cut tubing with the end square An angled cut or distortion of the tubing will not provide an efficient seal and may cause...

Страница 8: ...ace at least 2 in diameter Check the underside of the location for interference The standard faucet that is supplied with the system requires a diameter hole The optional air gap faucet requires a lar...

Страница 9: ...k top and let it rest on the sink top From the underside of the sink slide the washers onto the threaded stem as shown in the diagram 4 5 made of rubber 6 made of metal Secure the assembly by threadin...

Страница 10: ...e drill bit drill a hole in the drain pipe Use the drill bit to enlarge the hole Clean the debris from the pipe and the hole before continuing Notice Take extreme caution to not drill through to the o...

Страница 11: ...sink faucet to drain water and relieve pressure from the lines Assemble the Ball Valve Adapter Kit Use Teflon tape to wrap the threads of the ball valve approximately 3 wraps Screw the ball valve int...

Страница 12: ...t all tubing and fittings used for RO product water are poly material and not copper Due to RO product water being very pure it can leach the minerals from copper tubing which will cause a metallic ta...

Страница 13: ...em seal for leakage If necessary tighten stem nut lightly Turn storage tank valve one quarter turn counterclockwise to open the valve the handle should be in line with the tubing as it enters the conn...

Страница 14: ...Replace every 3 6 months Other Replacement Components Part Image H H14FWWA Filter Housing Standard 10 White FNPT PV2012PME Membrane Housing FNPT H S3200PW Storage Tank 3 2 gallon H R1000QC 100 GPD Flo...

Страница 15: ...to rinse the filter housings Leave the faucet open until the filter change is complete 1 Remove pre filters from filter housings Use a filter wrench if the housings are too tight 2 Discard used filte...

Страница 16: ...pump may be required Change in feedwater temperature The reverse osmosis membrane used in your unit is rated at 77 F and 60psi Water production will decrease approximately 1 5 for each degree that you...

Страница 17: ..._____________________________________________________ ____________________________________________________________ ____________________________________________________________ ________________________...

Страница 18: ..._____________________________________________________ ____________________________________________________________ ____________________________________________________________ ________________________...

Страница 19: ...not be liable for damages or delay caused by defective material Products returned to SELLER for warranty examination must be shipped freight prepaid SELLER S Liability SELLER SHALL NOT BE LIABLE FOR...

Страница 20: ...nt Pre filter Carbon Pre filter x 2 Carbon Post Filter Sediment Pre filter Carbon Pre filter x 2 Sediment Pre filter Carbon Pre filter x 2 Carbon Post Filter RO Membrane x 2 Sanitize System Replacemen...

Отзывы: