background image

Installation and Service Manual – Under-the-Counter Point of Use 5 Stage Reverse Osmosis System 

 

Copyright © 2019 WaterAnywhere  

All Rights Reserved.

 

Page 8 

 

 

Step 2 - Faucet Installation 

For this step, you will need: 

  Faucet assembly kit included with System 

  Tubing, cut to the appropriate length 

 Wrench 

 

 

Install the faucet onto the 
countertop/sink: 

  Find and identify all of the parts in the faucet bag, as 

shown in the diagram. 

  Add the metal washer (2), and then the rubber seal 

(3) onto the threaded nozzle of the faucet (1). 

  Place the faucet nozzle through the previously drilled 

hole in the countertop or sink top, and let it rest on the 
sink top. 

  From the underside of the sink, slide the washers 

onto the threaded stem as shown in the diagram. 

-  (4) & (5) - made of rubber 
-  (6) - made of metal 

 

  Secure the assembly by threading on the locking nut 

(7). 

  Check the orientation and alignment of the faucet and 

washers, adjust as necessary, then use a wrench to 
tighten the locking nut securely 

 Notice:

 

Do not overtighten fittings. 

Install the Tubing 

  Slide the metal nut (10) over the end of the tubing 

with the threads facing up. 

  Add the plastic clamp (9). 

  Press the plastic insert (8) into the end of the tubing. 

  Slide the tubing (until it 

stops) inside the faucet 
nozzle and screw it in by 
hand with the nut that 
was placed on the tubing 
earlier (10). 

  Connect the other end of 

the tubing to the elbow in 
the “out” end of the post 
filter.  

 

Содержание AAA-RO200W

Страница 1: ...ywhere com 760 727 1652 sales wateranywhere com Manual for Installation Operation and Maintenance of 5 Stage Point of Use Reverse Osmosis Drinking Water System Document ID AAARO200W Revision 05 13 20...

Страница 2: ...e 4 2 Reverse Osmosis Membranes Replace every 12 months The fourth stage is the reverse osmosis membrane which is the heart of the RO system To achieve a higher product water flow the water stream is...

Страница 3: ...ousings onto System Manifold 5 Prepare Tubing 6 Quick Connect Fittings and Tubing Connections 6 Installation Steps Step 1 Drill a Hole into the Sink for the Faucet 7 Step 2 Faucet Installation 8 Step...

Страница 4: ...water softener for hard water supplies will increase membrane life and efficiency Warnings Only use this system on potable water supplies Do not use this system where the water is microbiologically u...

Страница 5: ...housing D Housing with RO Membrane 2 in parallel E Four way Valve F In Line Cartridge with Activated Carbon G Flow Restrictor H Tank Valve I Tank J Faucet 1 Clean Water Outlets 2 Pollutants Outlets 3...

Страница 6: ...er hazards Determine the location of the cold water feed line to use for the system supply Notice Accidentally hooking up the system to the hot water supply line will permanently damage the membrane s...

Страница 7: ...s and Tubing Connections To ensure a secure seal using quick connect fittings Cut tubing with the end square An angled cut or distortion of the tubing will not provide an efficient seal and may cause...

Страница 8: ...ace at least 2 in diameter Check the underside of the location for interference The standard faucet that is supplied with the system requires a diameter hole The optional air gap faucet requires a lar...

Страница 9: ...k top and let it rest on the sink top From the underside of the sink slide the washers onto the threaded stem as shown in the diagram 4 5 made of rubber 6 made of metal Secure the assembly by threadin...

Страница 10: ...e drill bit drill a hole in the drain pipe Use the drill bit to enlarge the hole Clean the debris from the pipe and the hole before continuing Notice Take extreme caution to not drill through to the o...

Страница 11: ...sink faucet to drain water and relieve pressure from the lines Assemble the Ball Valve Adapter Kit Use Teflon tape to wrap the threads of the ball valve approximately 3 wraps Screw the ball valve int...

Страница 12: ...t all tubing and fittings used for RO product water are poly material and not copper Due to RO product water being very pure it can leach the minerals from copper tubing which will cause a metallic ta...

Страница 13: ...em seal for leakage If necessary tighten stem nut lightly Turn storage tank valve one quarter turn counterclockwise to open the valve the handle should be in line with the tubing as it enters the conn...

Страница 14: ...Replace every 3 6 months Other Replacement Components Part Image H H14FWWA Filter Housing Standard 10 White FNPT PV2012PME Membrane Housing FNPT H S3200PW Storage Tank 3 2 gallon H R1000QC 100 GPD Flo...

Страница 15: ...to rinse the filter housings Leave the faucet open until the filter change is complete 1 Remove pre filters from filter housings Use a filter wrench if the housings are too tight 2 Discard used filte...

Страница 16: ...pump may be required Change in feedwater temperature The reverse osmosis membrane used in your unit is rated at 77 F and 60psi Water production will decrease approximately 1 5 for each degree that you...

Страница 17: ..._____________________________________________________ ____________________________________________________________ ____________________________________________________________ ________________________...

Страница 18: ..._____________________________________________________ ____________________________________________________________ ____________________________________________________________ ________________________...

Страница 19: ...not be liable for damages or delay caused by defective material Products returned to SELLER for warranty examination must be shipped freight prepaid SELLER S Liability SELLER SHALL NOT BE LIABLE FOR...

Страница 20: ...nt Pre filter Carbon Pre filter x 2 Carbon Post Filter Sediment Pre filter Carbon Pre filter x 2 Sediment Pre filter Carbon Pre filter x 2 Carbon Post Filter RO Membrane x 2 Sanitize System Replacemen...

Отзывы: