background image

Installation and Service Manual – Under-the-Counter Point of Use 5 Stage Reverse Osmosis System 

 

Copyright © 2019 WaterAnywhere  

All Rights Reserved.

 

Page 10 

 

 

Step 4 – System Feed Line Installation 

For this step you will need: 

 ½” 

and 

7

/

16

” open-end wrenches (or two adjustable wrenches) 

 Teflon 

Tape 

  Feed Adapter & Ball Valve Kit 

 Tubing 

Locate and Turn Off the Cold Water Supply 

  Locate the valve in the cold water feed line you use for the supply.   

 Notice:

 

Accidentally hooking up the system to the hot water supply line will permanently 
damage the membrane (see conditions for operation).  To assure you are using the 
cold water line, turn on both the hot and cold faucet.  After the water is warm to the 
touch, feel the pipes under the sink.  It will be easy to identify the hot and cold pipes. 

 

  Close the cold water valve.   

  Turn on the sink faucet to drain water and relieve pressure from the lines.   

  If no shut off valve is located under the sink, or if water continues to come out of the faucet, turn off the 

main supply at the entry to the house, then turn on the sink faucet to drain water and relieve pressure from 
the lines. 

Assemble the Ball Valve & Adapter Kit 

  Use Teflon tape to wrap the threads of the ball valve – approximately 3 wraps.

 

 

  Screw the ball valve into the adapter.   

 

Install the Feed Adapter into the Cold Water Supply 

 

  Wrap the slip joint adapter with Teflon tape, approximately 3 wraps. 

 

For Flex Line:   

Loosen nut and separate cold water riser tube from faucet 

shank.  Gently bend riser rube so that slip joint fits onto faucet shank.   Make 
sure the flat washer is on top and the cone washer is on the bottom.   
Reinstall riser tubes onto slip joint adapter and tighten.   
 

 

For Solid Copper Riser Tube

: Same procedure as flex tubing except you 

must cut a piece of the riser tube about ¾” to 1” so the slip joint adapter can 
fit between faucet and riser tube. 
 

Connect the Feed Line Tubing  

  Unscrew the nut from the ball valve.  Slide the nut onto the tubing, threaded sides facing the end of the 

tubing.  Feed the nipple on the ball valve into the 
tubing, pushing the tubing until it slides over the lip.  
Slide the nut to the threads on the ball valve, and 
tighten the nut down over the tubing.   Use a wrench to 
tighten ¼ turn past finger-tight. 

  Connect the other end of the tubing to the feed port on 

the RO System. 

Содержание AAA-RO200W

Страница 1: ...ywhere com 760 727 1652 sales wateranywhere com Manual for Installation Operation and Maintenance of 5 Stage Point of Use Reverse Osmosis Drinking Water System Document ID AAARO200W Revision 05 13 20...

Страница 2: ...e 4 2 Reverse Osmosis Membranes Replace every 12 months The fourth stage is the reverse osmosis membrane which is the heart of the RO system To achieve a higher product water flow the water stream is...

Страница 3: ...ousings onto System Manifold 5 Prepare Tubing 6 Quick Connect Fittings and Tubing Connections 6 Installation Steps Step 1 Drill a Hole into the Sink for the Faucet 7 Step 2 Faucet Installation 8 Step...

Страница 4: ...water softener for hard water supplies will increase membrane life and efficiency Warnings Only use this system on potable water supplies Do not use this system where the water is microbiologically u...

Страница 5: ...housing D Housing with RO Membrane 2 in parallel E Four way Valve F In Line Cartridge with Activated Carbon G Flow Restrictor H Tank Valve I Tank J Faucet 1 Clean Water Outlets 2 Pollutants Outlets 3...

Страница 6: ...er hazards Determine the location of the cold water feed line to use for the system supply Notice Accidentally hooking up the system to the hot water supply line will permanently damage the membrane s...

Страница 7: ...s and Tubing Connections To ensure a secure seal using quick connect fittings Cut tubing with the end square An angled cut or distortion of the tubing will not provide an efficient seal and may cause...

Страница 8: ...ace at least 2 in diameter Check the underside of the location for interference The standard faucet that is supplied with the system requires a diameter hole The optional air gap faucet requires a lar...

Страница 9: ...k top and let it rest on the sink top From the underside of the sink slide the washers onto the threaded stem as shown in the diagram 4 5 made of rubber 6 made of metal Secure the assembly by threadin...

Страница 10: ...e drill bit drill a hole in the drain pipe Use the drill bit to enlarge the hole Clean the debris from the pipe and the hole before continuing Notice Take extreme caution to not drill through to the o...

Страница 11: ...sink faucet to drain water and relieve pressure from the lines Assemble the Ball Valve Adapter Kit Use Teflon tape to wrap the threads of the ball valve approximately 3 wraps Screw the ball valve int...

Страница 12: ...t all tubing and fittings used for RO product water are poly material and not copper Due to RO product water being very pure it can leach the minerals from copper tubing which will cause a metallic ta...

Страница 13: ...em seal for leakage If necessary tighten stem nut lightly Turn storage tank valve one quarter turn counterclockwise to open the valve the handle should be in line with the tubing as it enters the conn...

Страница 14: ...Replace every 3 6 months Other Replacement Components Part Image H H14FWWA Filter Housing Standard 10 White FNPT PV2012PME Membrane Housing FNPT H S3200PW Storage Tank 3 2 gallon H R1000QC 100 GPD Flo...

Страница 15: ...to rinse the filter housings Leave the faucet open until the filter change is complete 1 Remove pre filters from filter housings Use a filter wrench if the housings are too tight 2 Discard used filte...

Страница 16: ...pump may be required Change in feedwater temperature The reverse osmosis membrane used in your unit is rated at 77 F and 60psi Water production will decrease approximately 1 5 for each degree that you...

Страница 17: ..._____________________________________________________ ____________________________________________________________ ____________________________________________________________ ________________________...

Страница 18: ..._____________________________________________________ ____________________________________________________________ ____________________________________________________________ ________________________...

Страница 19: ...not be liable for damages or delay caused by defective material Products returned to SELLER for warranty examination must be shipped freight prepaid SELLER S Liability SELLER SHALL NOT BE LIABLE FOR...

Страница 20: ...nt Pre filter Carbon Pre filter x 2 Carbon Post Filter Sediment Pre filter Carbon Pre filter x 2 Sediment Pre filter Carbon Pre filter x 2 Carbon Post Filter RO Membrane x 2 Sanitize System Replacemen...

Отзывы: