background image

Installation and Service Manual – Under-the-Counter Point of Use 5 Stage Reverse Osmosis System 

 

Copyright © 2019 WaterAnywhere  

All Rights Reserved.

 

Page 13 

 

 

Replacement 

Parts 

           

 

Sediment Pre-Filter,  
5 Micron.   
Stage 1 
 

Model:  H-F1005CF  

Qty. 1 Per System 

Replace every 3-6 months

 

 

Carbon Pre-Filter,  
Extruded Carbon 
Stage 2 & 3 
 

Model:  H-F2510AC 

Qty. 2 Per System 

Replace every 3-6 months

 

 

Replacement Filter Kits: 

 

RFK-5:  

Pre & Post Filters 

RFK-5-PRE:  

Pre-Filters Only 

 

RFK-5-50 (50 gpd) 

RFK-5-100 (100 gpd) 

One complete set of prefilters, post 

filter, and membrane. 

See back cover for replace schedule.

 

Membrane Elements 
Stage 4 
(2 in Parallel) 
 

Model:  1812-100-RO  

Qty. 2 Per System 

Replace every 12 months

 

 

Carbon Post-Filter,  
GAC Inline 
Stage 5 
 

Model:  H-F1032-43A 

Qty. 1 Per System 

Replace every 3-6 months

 

 

Other Replacement Components 

Part 

Image 

H-H14FWWA 

Filter Housing 
Standard 10” 
White,  ¼” FNPT

 

 

PV2012PME 

Membrane Housing 

” FNPT

 

 

H-S3200PW 

Storage Tank 
3.2 gallon

 

 

H-R1000QC  

100 GPD Flow Restrictor

 

 

H-J2021KW 

Clip, Membrane Housing 
to In-line Filter

 

 

H-J2025PW 

Clip, Membrane Housing 
to Bracket

 

 

 

Part 

Image 

H-T5000 

Faucet, Non-Airgap, 
Long-Reach

 

 

H-V1050W-QC 

Auto Shut-Off Valve

 

 

H-S3200TV 

Tank Shut-Off Valve

 

 

H-V1009 

Feed Valve and 
Adapter

 

 

H-D3000M 

Drain Saddle

 

 

H-C9200FWWA 

Wrench for Filter 
Housing

 

 

OR-H10FWWA-SET 

O-Ring Set for Filter 
Housing.  Top & 
Bottom.

 

 

 

Part 

Image 

TUBE-10FT-14-WH

 

White Tubing 

10 foot pack

 

 

PN-4-P 

¼” Hex Nipple 

(connects filter housing 

to filter housing)

 

 

F-4MBT44QC 

¼” Male to ¼”QC 

Branch Tee (for post 

filter inlet)

 

 

PI480822S 

Elbow Fitting 

¼” MNPT × ¼” QC (for 

filter housings & post 

filter outlet) 

 

PI480821S 

Elbow Fitting 

” MNPT × ¼” QC (for 

membrane housing)

 

 

H-V1003 

Check Valve, installed 

in ¼” Elbow 

(membrane permeate)

 

 

H-B2031W 

Mounting Bracket

 

 

 

 

 

Содержание AAA-RO200W

Страница 1: ...ywhere com 760 727 1652 sales wateranywhere com Manual for Installation Operation and Maintenance of 5 Stage Point of Use Reverse Osmosis Drinking Water System Document ID AAARO200W Revision 05 13 20...

Страница 2: ...e 4 2 Reverse Osmosis Membranes Replace every 12 months The fourth stage is the reverse osmosis membrane which is the heart of the RO system To achieve a higher product water flow the water stream is...

Страница 3: ...ousings onto System Manifold 5 Prepare Tubing 6 Quick Connect Fittings and Tubing Connections 6 Installation Steps Step 1 Drill a Hole into the Sink for the Faucet 7 Step 2 Faucet Installation 8 Step...

Страница 4: ...water softener for hard water supplies will increase membrane life and efficiency Warnings Only use this system on potable water supplies Do not use this system where the water is microbiologically u...

Страница 5: ...housing D Housing with RO Membrane 2 in parallel E Four way Valve F In Line Cartridge with Activated Carbon G Flow Restrictor H Tank Valve I Tank J Faucet 1 Clean Water Outlets 2 Pollutants Outlets 3...

Страница 6: ...er hazards Determine the location of the cold water feed line to use for the system supply Notice Accidentally hooking up the system to the hot water supply line will permanently damage the membrane s...

Страница 7: ...s and Tubing Connections To ensure a secure seal using quick connect fittings Cut tubing with the end square An angled cut or distortion of the tubing will not provide an efficient seal and may cause...

Страница 8: ...ace at least 2 in diameter Check the underside of the location for interference The standard faucet that is supplied with the system requires a diameter hole The optional air gap faucet requires a lar...

Страница 9: ...k top and let it rest on the sink top From the underside of the sink slide the washers onto the threaded stem as shown in the diagram 4 5 made of rubber 6 made of metal Secure the assembly by threadin...

Страница 10: ...e drill bit drill a hole in the drain pipe Use the drill bit to enlarge the hole Clean the debris from the pipe and the hole before continuing Notice Take extreme caution to not drill through to the o...

Страница 11: ...sink faucet to drain water and relieve pressure from the lines Assemble the Ball Valve Adapter Kit Use Teflon tape to wrap the threads of the ball valve approximately 3 wraps Screw the ball valve int...

Страница 12: ...t all tubing and fittings used for RO product water are poly material and not copper Due to RO product water being very pure it can leach the minerals from copper tubing which will cause a metallic ta...

Страница 13: ...em seal for leakage If necessary tighten stem nut lightly Turn storage tank valve one quarter turn counterclockwise to open the valve the handle should be in line with the tubing as it enters the conn...

Страница 14: ...Replace every 3 6 months Other Replacement Components Part Image H H14FWWA Filter Housing Standard 10 White FNPT PV2012PME Membrane Housing FNPT H S3200PW Storage Tank 3 2 gallon H R1000QC 100 GPD Flo...

Страница 15: ...to rinse the filter housings Leave the faucet open until the filter change is complete 1 Remove pre filters from filter housings Use a filter wrench if the housings are too tight 2 Discard used filte...

Страница 16: ...pump may be required Change in feedwater temperature The reverse osmosis membrane used in your unit is rated at 77 F and 60psi Water production will decrease approximately 1 5 for each degree that you...

Страница 17: ..._____________________________________________________ ____________________________________________________________ ____________________________________________________________ ________________________...

Страница 18: ..._____________________________________________________ ____________________________________________________________ ____________________________________________________________ ________________________...

Страница 19: ...not be liable for damages or delay caused by defective material Products returned to SELLER for warranty examination must be shipped freight prepaid SELLER S Liability SELLER SHALL NOT BE LIABLE FOR...

Страница 20: ...nt Pre filter Carbon Pre filter x 2 Carbon Post Filter Sediment Pre filter Carbon Pre filter x 2 Sediment Pre filter Carbon Pre filter x 2 Carbon Post Filter RO Membrane x 2 Sanitize System Replacemen...

Отзывы: