System Mounting 

 

 

 

 

 

 

 

 

 

 

 

Wall mounting is recommended for this system.   Dry wall anchors and screws may be necessary (not included 
with the system). 

  Mark screw locations at the desired positions.  Use the two holes on the back of the RO System mounting 

bracket for marker guides. 

  Screw the screws into the mounting wall on the marked positions.  Use an anchoring device appropriate for 

the type of material you are screwing into. 

  Hang the purification system onto the screws by the holes on the back of the unit. 

 
 

Turning the System On for the 

First 

Time 

     

Make sure all water supply and drain line connections are secure and free from leaks. 

Slowly turn the feed valve counterclockwise until fully open (the handle should be in line with the tubing as it 
enters the connection).   Check the stem seal for leakage.  If necessary, tighten stem nut lightly. 

Turn storage tank valve one quarter turn counterclockwise to open the valve (the handle should be in line with 
the tubing as it enters the connection). 

Open the product water faucet and let the water flow until all the air has been expelled from the system.  This 
will take about an hour. 

Close the product water faucet.  In 30 minutes, check the system and connections for leaks and correct if 
necessary. 

 

Do Not Use the First Two Reservoirs of Water 

Allow the reservoir to fill for 4-6 hours.  Dispense this water to drain.  This process 
removes the factory installed sanitizing solution from the entire system and sends it to 
the drain.  Repeat this process one more time.  Allow the tank to fill for 4-6 hours and 
dispense this water to the drain.  Do not drink this water! 

 

 Notice:

 

Air bubbles may be present in the product water after initial system startup, causing a 
milky color in the water.  This is normal and safe to drink.  The air bubbles will 
disappear within a few days of regular use. 

 

 

 Notice:

 

Check back frequently in the first 24 hours to ensure no leaking has occurred. 

 

 

 

Содержание AAA-RO200W

Страница 1: ...ywhere com 760 727 1652 sales wateranywhere com Manual for Installation Operation and Maintenance of 5 Stage Point of Use Reverse Osmosis Drinking Water System Document ID AAARO200W Revision 05 13 20...

Страница 2: ...e 4 2 Reverse Osmosis Membranes Replace every 12 months The fourth stage is the reverse osmosis membrane which is the heart of the RO system To achieve a higher product water flow the water stream is...

Страница 3: ...ousings onto System Manifold 5 Prepare Tubing 6 Quick Connect Fittings and Tubing Connections 6 Installation Steps Step 1 Drill a Hole into the Sink for the Faucet 7 Step 2 Faucet Installation 8 Step...

Страница 4: ...water softener for hard water supplies will increase membrane life and efficiency Warnings Only use this system on potable water supplies Do not use this system where the water is microbiologically u...

Страница 5: ...housing D Housing with RO Membrane 2 in parallel E Four way Valve F In Line Cartridge with Activated Carbon G Flow Restrictor H Tank Valve I Tank J Faucet 1 Clean Water Outlets 2 Pollutants Outlets 3...

Страница 6: ...er hazards Determine the location of the cold water feed line to use for the system supply Notice Accidentally hooking up the system to the hot water supply line will permanently damage the membrane s...

Страница 7: ...s and Tubing Connections To ensure a secure seal using quick connect fittings Cut tubing with the end square An angled cut or distortion of the tubing will not provide an efficient seal and may cause...

Страница 8: ...ace at least 2 in diameter Check the underside of the location for interference The standard faucet that is supplied with the system requires a diameter hole The optional air gap faucet requires a lar...

Страница 9: ...k top and let it rest on the sink top From the underside of the sink slide the washers onto the threaded stem as shown in the diagram 4 5 made of rubber 6 made of metal Secure the assembly by threadin...

Страница 10: ...e drill bit drill a hole in the drain pipe Use the drill bit to enlarge the hole Clean the debris from the pipe and the hole before continuing Notice Take extreme caution to not drill through to the o...

Страница 11: ...sink faucet to drain water and relieve pressure from the lines Assemble the Ball Valve Adapter Kit Use Teflon tape to wrap the threads of the ball valve approximately 3 wraps Screw the ball valve int...

Страница 12: ...t all tubing and fittings used for RO product water are poly material and not copper Due to RO product water being very pure it can leach the minerals from copper tubing which will cause a metallic ta...

Страница 13: ...em seal for leakage If necessary tighten stem nut lightly Turn storage tank valve one quarter turn counterclockwise to open the valve the handle should be in line with the tubing as it enters the conn...

Страница 14: ...Replace every 3 6 months Other Replacement Components Part Image H H14FWWA Filter Housing Standard 10 White FNPT PV2012PME Membrane Housing FNPT H S3200PW Storage Tank 3 2 gallon H R1000QC 100 GPD Flo...

Страница 15: ...to rinse the filter housings Leave the faucet open until the filter change is complete 1 Remove pre filters from filter housings Use a filter wrench if the housings are too tight 2 Discard used filte...

Страница 16: ...pump may be required Change in feedwater temperature The reverse osmosis membrane used in your unit is rated at 77 F and 60psi Water production will decrease approximately 1 5 for each degree that you...

Страница 17: ..._____________________________________________________ ____________________________________________________________ ____________________________________________________________ ________________________...

Страница 18: ..._____________________________________________________ ____________________________________________________________ ____________________________________________________________ ________________________...

Страница 19: ...not be liable for damages or delay caused by defective material Products returned to SELLER for warranty examination must be shipped freight prepaid SELLER S Liability SELLER SHALL NOT BE LIABLE FOR...

Страница 20: ...nt Pre filter Carbon Pre filter x 2 Carbon Post Filter Sediment Pre filter Carbon Pre filter x 2 Sediment Pre filter Carbon Pre filter x 2 Carbon Post Filter RO Membrane x 2 Sanitize System Replacemen...

Отзывы: