Page 26
WS1HR & WS1.25HR Manual
STEP 1D – Press
▲
and
▼
simultaneously for three seconds. If screen in step 2D does not appear in
5 seconds the lock on the valve is activated. To unlock press
▲
, NEXT,
▼
, and CLOCK in sequence,
then press
▲
and
▼
simultaneously for 3 seconds.
STEP 2D
– Days, since last regeneration: This display shows the days since the last regeneration oc-
curred. Press the NEXT button to go to Step 3D. Press REGEN to exit Diagnostics.
STEP 3D – Volume, since last regeneration: This display shows the volume of water that has been
treated since the last regeneration. This display will equal zero if a water meter is not installed. Press
the NEXT button to go to Step 4D. Press REGEN to return to previous step.
STEP 4D – Volume, reserve capacity used for last 7 days: If the valve is
set up as a softener, a meter is installed and Set Volume Capacity is set
to “Auto,” this display shows 0 day (for today) and fl ashes the reserve
capacity. Pressing the
▲
button will show day 1 (which would be yester-
day) and fl ashes the reserve capacity used. Pressing the
▲
button again will show day 2 (the day before
yesterday) and the reserve capacity. Keep pressing the
▲
button to show the capacity for days 3, 4, 5
and 6. The
▼
button can be pressed to move backwards in the day series. Press the NEXT button at
any time to go to Step 5D. Press REGEN to return to previous step.
STEP 5D - Volume, 63-day usage history: This display shows day 1 (for
yesterday) and fl ashes the volume of water treated yesterday. Pressing
the
▲
button will show day 2 (which would be the day before yesterday)
and fl ashes the volume of water treated on that day. Continue to press the
▲
button to show the maximum volume of water treated for the last 63 days. If a regeneration occured
on the day the word “REGEN” will also be displayed. This display will show dashes if a water meter is
not installed. Press the NEXT button at any time to go to Step 6D. Press REGEN to return to previous
step.
STEP 6D – Flow rate, maximum last seven days: The maximum fl ow rate in gallons per minute that
occurred in the last seven days will be displayed. This display will equal zero if a water meter is not
installed. Press the NEXT button to exit Diagnostics. Press REGEN to return to previous step.
STEP 1D
STEP 2D
STEP 3D
STEP 6D
RETURN TO NORMAL MODE
STEP 4D
STEP 5D
When desired, all information in Diagnostics may be reset to zero when the valve is installed in a new location. To reset
to zero, press NEXT and
▼
buttons simultaneously to go to the Service/OEM 1 screen, and release. Press
▲
and
▼
simultaneously to reset diagnostic values to zero. Screen will return to User Display.
Diagnostics
➟
Содержание WS1HR
Страница 2: ......
Страница 13: ...WS1HR WS1 25HR Manual Page 13 Figure 3 Figure 4 Figure 1 Figure 2...
Страница 30: ...Page 30 WS1HR WS1 25HR Manual Drawings and Part Numbers...
Страница 42: ...Page 42 WS1HR WS1 25HR Manual Flow Diagrams Service and Backwash...
Страница 43: ...WS1HR WS1 25HR Manual Page 43 Flow Diagrams Downflow and Upflow WS1HR Only...
Страница 44: ...Page 44 WS1HR WS1 25HR Manual Flow Diagrams Rinse and Fill...
Страница 54: ...Page 54 WS1HR WS1 25HR Manual...
Страница 55: ...WS1HR WS1 25HR Manual Page 55...
Страница 56: ...Page 56 WS1HR WS1 25HR Manual...
Страница 57: ...WS1HR WS1 25HR Manual Page 57...
Страница 58: ...Page 58 WS1HR WS1 25HR Manual...
Страница 59: ...WS1HR WS1 25HR Manual Page 59...