background image

 

1.2. What You Get 

 
Below is a list of parts included with system. 
 
Item 

Description 

Quantity

Image 

1. 

Main control unit

 

 

 

 

 

The unit incorporates a powerful siren, flashing blue 
strobe & backup battery to run the system in case of mains 
power failure. There is also a tamper button.  The system 
has mains connection via a low voltage plug pack that is 
supplied with the unit. For manual override of the system 
there is a keyswitch on the main unit.

 

2. 

Remote controls

 

 

 

 

2 x High Security Code Hopping Remote Controls. These 
allow you to easily arm & disarm the system from 
anywhere in your home. In case of duress, you can trigger 
the alarm at any time from the remote control.  

 

3. 

Power Supply (plug pack) 

 

 

The main unit requires a regular mains power supply.  
The Watchguard is supplied with a 9V AC plug pack that 
connects to the main unit. 

 

4. 

Screamer

 

 

 

 

This high frequency siren generates an intolerable noise to 
the human ear, and is designed to help repel intruders from 
within your home. It mounts easily to the roof of one of 
your rooms, and is simply cabled back to the main control 
unit (10m of cable is provided).  

 

5. 

Passive Infrared Detectors 

 

 

 

   

 

Designed to detect the body movement of an intruder 
inside your premises. These intelligent devices allow 
simple installation, as no cable is required between the 
main unit and the detectors. The long life lithium batteries 
will last for up to 3 years, and the system will 
automatically let you know when the batteries need 
replacing. 
 

6. 

High Security – Override keys 

 

 

 

Used for manually overriding the system if both remote 
controls are lost and also when the system is not being 
used (in storage). 

7. 

Mounting Material & Screws 

 
 

 

 

4 large pan head screws, 4 green star plugs (for main unit), 
4 medium counter sunk gyprock screws (for screamer), 2 
wall plugs, 2 small counter sunk self tapping screws and 
mounting brackets (for detectors).

 

 

Содержание N517Series II

Страница 1: ...Watchguard Home Alarm System Series II Document Watch Guard V2 2 doc Release 27 February 2007 I n s t r u c t i o n s Designed in Australia and Manufactured in Taiwan by N517...

Страница 2: ...6 Low Battery Reporting 15 3 7 Supervision Reporting 16 3 8 The Passive Infrared Detectors 16 3 8 1 Test Mode for the Passive Infrared detectors 16 3 8 2 Intelligent Power Saving and Normal Operation...

Страница 3: ...5 2 The Remote Control 35 5 3 The Detector 35 5 3 1 Replacing the batteries 35 5 3 2 Cleaning the pyro detector 36 5 3 3 Cleaning the case and lense 36 6 Warranty 37 6 1 Warning Limitations Warranty 3...

Страница 4: ...ogy remotes can not be copied by scanning or code grabbing Remote Functions include arm disarm stay mode and panic Ability to add or erase detectors from your system 8 Wireless detector zones availabl...

Страница 5: ...with your fingers During the warm up period first 3 minutes after installing the batteries the detector will not respond to the tamper switch or to movement in front of the detector You must wait 3 m...

Страница 6: ...4 Screamer 1 This high frequency siren generates an intolerable noise to the human ear and is designed to help repel intruders from within your home It mounts easily to the roof of one of your rooms a...

Страница 7: ...nning and Wire Routing 1 The Watchguard main unit should be located high on the front or front side of the building under an eave of covering See Section 2 2 2 Route the white white black wire 2 core...

Страница 8: ...ugs and screws provided if suitable for your particular building construction Installing the main unit 1 Drill mounting holes 7mm diameter 25mm minimum in depth into the chosen wall 2 Use the green st...

Страница 9: ...a corridor or hallway 2 Feed the wire coming from the screamer up through the 15mm hole into the ceiling where it will join the wire from the main unit 3 Push the screamer on to the ceiling aligning...

Страница 10: ...tallation have a power point installed in the ceiling by a qualified electrician so that the power supply plug pack is hidden and unable to be accessed easily Another location for the power supply wou...

Страница 11: ...he detector on your wall using the swivel mount provided at a minimum height of 1 2 metres and maximum of 2 1 metres lower is better Make sure the detector is a minimum of 5 metres away from your main...

Страница 12: ...een cleared and the detector is still not responding then remove the batteries which the plastic was covering Lift the bottom terminals and push down the top terminals for tighter battery connections...

Страница 13: ...he system in STAY mode The siren will beep on each press The second beep will be a low tone PANIC mode Press and hold approximately 3 seconds to activate PANIC mode Press Button 2 DISARMING Press once...

Страница 14: ...area s of the building while you and others are on the premises or someone is STAYING home Commonly used at night while sleeping Indications The siren will beep once on the first press and will then m...

Страница 15: ...or more of the following 1 beep Zone 1 has a low battery 6 beeps Zone 6 has a low battery 2 beeps Zone 2 has a low battery 7 beeps Zone 7 has a low battery 3 beeps Zone 3 has a low battery 8 beeps Zo...

Страница 16: ...ow is the best way of checking the detector At 25 Celsius the detector should have a detection range of approximately 10 metres and a scope angle of 90 i e 45 either side of the center position straig...

Страница 17: ...ady to sense for any movement in the room If the detector detects another valid body movement anytime after the 3 minutes of IPS then it will go back into IPS mode again for 3 minutes and so on There...

Страница 18: ...attern in an optimal temperature environment is shown in figure 9 and figure 10 Each time you walk into or out of an infrared beam zone this will be sensed and processed by the DES technology built in...

Страница 19: ...ll create a third pulse If the detector is set to least sensitive default and the body moves from position 1 to position 4 within 10 seconds then the detector will have received 3 pulses in 10 seconds...

Страница 20: ...trigger body movements are body movements which are too small to be recognized as valid body movements to trigger the detector In the example shown by figure 14 a body walking into one side of the in...

Страница 21: ...green lights flash 6 times If the detector has low battery voltage then the red light will flash an additional 6 times in a row The detector will send a low battery radio transmission to your Watchgu...

Страница 22: ...and making mistakes If at any stage you become lost or forget where you are up to stop and wait for the 3 low toned beeps that tell you that the alarm timed out of programming mode and no changes will...

Страница 23: ...beeps finish press and hold down button 2 on the new remote control for 3 seconds 5 Press new remote control to test The new remote control is now programmed into the alarm To confirm this press Butt...

Страница 24: ...On the first press you will hear a beep On the second press you will hear a low tone beep 3 Press 7 times within 8 secs Within 3 seconds of STAY arming press Button 1 another 7 times within 8 seconds...

Страница 25: ...ming You will hear 1 beep as confirmation 4 Press 1 time Within 30 seconds press Button 1 to ADD a detector You will hear 1 beep as confirmation 5 Open the detector you wish to add Trigger the detecto...

Страница 26: ...Walk Test mode During this time the siren will beep the number of times of the zone which has been triggered Label the detector with its zone number for future reference Detectors which have been set...

Страница 27: ...detector You will hear 2 beeps as confirmation 5 Press the number of times of the zone you want to delete Within 5 seconds press Button 1 The first beep you hear indicates zone 1 Each additional pres...

Страница 28: ...firm you have entered programming mode 3 Press 1 time Within 3 seconds press Button 2 to select special features You will hear 2 beeps as confirmation 4 Press 1 time Within 30 seconds press Button 2 t...

Страница 29: ...rogramming mode 3 Press 1 time Within 3 seconds press Button 2 to select special features You will hear 2 beeps as confirmation 4 Press 1 time Within 30 seconds press Button 1 to hear the Alarm Memory...

Страница 30: ...e is triggered This only applies to STAY mode Default Entry Guard Tones Option 1 Full Siren TO CHANGE THE STAY MODE ENTRY GUARD SOUND 1 Safety Lock must be off Ensure Safety Lock has been turned off w...

Страница 31: ...conds Press to choose Entry Guard Tones OR Press to choose Full Siren Thes option will enable Entry Guard tones when the system is triggered in STAY mode This option will sound the steady siren when t...

Страница 32: ...pressing buttons 1 2 together for 3 seconds The siren will beep 3 times to confirm you have entered programming mode 3 Press 1 time Within 3 seconds press Button 2 to select special features You will...

Страница 33: ...f then back on again c Within 15 seconds of turning the keyswitch to on press in the tamper switch 20 times NOTE On system power up the tamper will not respond for the first 15 seconds d When the syst...

Страница 34: ...plug pack is connected The system has a self test function and will report a low back up battery on disarming See Section 2 6 To test manually Disconnect the Power Supply and ensure the system will a...

Страница 35: ...ery connection Fingerprints can be cleaned off the batteries with a soft cloth and some alcohol solution The new batteries can now be slid into the battery holders making sure that the top terminal is...

Страница 36: ...lense Detectors are often left in position for long periods and spiders or other pests might stay around the detector It is important that the lens especially is kept clean of any spider webs or pests...

Страница 37: ...e of closed doors Smoke detectors may not sense a fire on another level of a residence or building A second floor detector for example may not sense a first floor or garage fire Moreover smoke detecto...

Страница 38: ...ce with Sellers specifications or proves defective in materials or workmanship under normal use and service Seller shall have no obligation under this Limited Warranty or otherwise if the product is a...

Страница 39: ...y will not be given where a product has been immersed in water under any circumstances or where damage has been caused by hosing the main unit without all due care taken by the owner to protect the ma...

Страница 40: ...ything possible to ensure that you are happy with your decision and that you have years of satisfaction from your Watchguard System We take extreme care in the research design and development of our p...

Отзывы: