Notice
Date
Page
01201055
INSTRUCTION
HANDBOOK
9
4807
Dead load selector
Scale unit
Connectors,
load cells
Connector, CPU
communication
Connector, power supply
Calibration switch
1000-
1330
280-
650
228
0-
2600
20
20
-
23
50
58
0-
88
0
830
-
113
0
1
730
-
2
050
15
00
-
18
30
123
0-
153
0
DEAD
LOAD
1100
74
11
11. Machine
operation
Fig.
9
Error message on display :
Failed. Press SELECT.
Possible causes :
Dead load selector or calibration switch incorrectly set. An incorrect calibration weight has been
used for calibration.
Fault-finding procedure :
•
Check that the dead load selector is set correctly. It should be set to 580-880 kg (machines
230-340-470) or 830-1130 kg (machine 670).
• If you are or have recently been calibrating the weighing equipment, the calibration switch
may be incorrectly set, or an incorrect calibration weight may have been used for calibration.
Check that the calibration switch is set correctly. It should normally be set to NORM
(normal). During calibration the switch should be set to CAL (calibrage).
The calibration weight should be between 40 and 400 kg.
If relevant/necessary, calibrate the weighing equipment, or follow the "Calibrate the scale"
procedure under "Machine operation".
•
Check that all cables/wiring to the scale unit are sound and correctly connected.