INSTRUCTION
HANDBOOK
0999
50
11
11. Machine
operation
(for machines with weighing equipment installed only)
4791
SCALE ADJUSTMENTS
DONE !
PRESS SELECT
CALIBRATE THE SCALE
4795
RESET SCALE FROM CALIBRATION
MODE AND PRESS SELECT
SCALE ADJUSTMENTS
CALIBRATE THE SCALE
Restore the calibration
switch to normal
mode.
Press SELECT.
Press SELECT.
4758
ON (normal)
Scale unit
Calibration switch
CAL (calibrage)
Calibration mode/normal mode
To gain access to the calibration switch in the scale
unit, the left-hand rear side panel has to be taken off.
Remove the four screws on the scale unit cover.
Then the calibration switch can be switched between
normal mode "ON" and calibration mode "CAL".