Sensor Failure (SF) messages by WECS
Code
Message
Reason
Action
BAG0_1T001SF
SF, Generator
winding temp., L1,
TE753
Sensor broken or
wiring fault (broken
or loose connections)
Check acc. to Fig 08-1. PT-100 sensor
failure
BAG0_1T002SF
SF, Generator
winding temp., L2,
TE754
Sensor broken or
wiring fault (broken
or loose connections)
Check acc. to Fig 08-1. PT-100 sensor
failure
BAG0_1T003SF
SF, Generator
winding temp., L3,
TE755
Sensor broken or
wiring fault (broken
or loose connections)
Check acc. to Fig 08-1. PT-100 sensor
failure
SVH0_1P003SF
SF, HT water pressure,
inlet, PT401
Sensor broken or
wiring fault (broken
or loose connections)
Check acc. to Fig 08-3. 4-20 mA
sensor failure
SVH0_1T006SF
SF, HT water temp.,
inlet, TE401
Sensor broken or
wiring fault (broken
or loose connections)
Check acc. to Fig 08-1. PT-100 sensor
failure
SVH0_1T013SF
SF, HT water temp.,
outlet, TE402
Sensor broken or
wiring fault (broken
or loose connections)
Check acc. to Fig 08-1. PT-100 sensor
failure
SVL0_1T005SF
SF, LT water temp.,
inlet, TE451
Sensor broken or
wiring fault (broken
or loose connections)
Check acc. to Fig 08-1. PT-100 sensor
failure
SVL0_1T006SF
SF, LT water temp.,
outlet, TE452
Sensor broken or
wiring fault (broken
or loose connections)
Check acc. to Fig 08-1. PT-100 sensor
failure
SQA0_1P008SF
SF, Lube oil pressure,
inlet, PT201
Sensor broken or
wiring fault (broken
or loose connections)
Check acc. to Fig 08-3. 4-20 mA
sensor failure
SQA0_1T003SF
SF, Lube oil temp.,
inlet, TE201
Sensor broken or
wiring fault (broken
or loose connections)
Check acc. to Fig 08-1. PT-100 sensor
failure
SQA0_1T004SF
SF, Lube oil temp.,
outlet, TE202
Sensor broken or
wiring fault (broken
or loose connections)
Check acc. to Fig 08-1. PT-100 sensor
failure
SOC0_1T0nnSF
SF, Main bearing n
temperature
Sensor broken or
wiring fault (broken
or loose connections)
Check acc. to Fig 08-2.
Thermocouple sensor failure
SZA0_1P001SF
SF, Main gas pressure,
PT901
Sensor broken or
wiring fault (broken
or loose connections)
Check acc. to Fig 08-4 4-20 mA sensor
failure MCU
SZA0_1P002SF
SF, PCC gas pressure,
PT911 *)
Sensor broken or
wiring fault (broken
or loose connections)
Check acc. to Fig 08-4 4-20 mA sensor
failure MCU
STA0_1P003SF
SF, Starting air
pressure, PT301
Sensor broken or
wiring fault (broken
or loose connections)
Check acc. to Fig 08-3. 4-20 mA
sensor failure
DCU0_1T001SF
SF, Temp. in DCU1,
TE831
Internal temperature
measurement of I/O
board broken
Replace I/O board
DCU0_1T002SF
SF, Temp. in DCU2,
TE832
Internal temperature
measurement of I/O
board broken
Replace I/O board
*) only dual gas line system
Operating Troubles
34SG-200414-04
Содержание 41508
Страница 3: ......
Страница 12: ...Appendix B Welding Precautions 200147...
Страница 22: ...Fuel Lubricating Oil Cooling Water 34SG 200303 03...
Страница 29: ...A Ap pp pe en nd di ix x A A E En nv vi ir ro on nm me en nt ta al l H Ha az za ar rd ds s 2 20 00 03 32 21 1...
Страница 73: ...Maintenance Tools 32 9801...
Страница 115: ...Engine Block with Bearings Cylinder and Oil Sump 34SG 9701...