![WÄRTSILÄ 41508 Скачать руководство пользователя страница 102](http://html1.mh-extra.com/html/wartsila/41508/41508_instruction-manual_3466519102.webp)
Alarm (ALM) messages by PLC
Code
Message
Reason
Action
SQA0_1P005AH
ALM, Lub.oil filter diff.
pressure
Lubrication oil filter
clogged
Check and clean the lubrication
filter
CFC0_1S021ALI
ALM, Power Monitor
Unit fault
Generator power
monitoring unit
internal fault
Check the power monitoring unit
display or use the power monitoring
unit program (VAMPSet) to identify
the problem
QEP0_1M001MFI
ALM, Prelube motor
control center fault
Prelube motor
overcurrent/shortcircu
it tripped
Check the overcurrent/shortcircuit
relay
QEP0_1M001AFI
ALM, Prelube pump
Start/Stop fault
Prelube motor
activation is not
according to given
command
Check the functionality of the main
contactor, Check the wiring for
running information and start/stop
commands
VCA0_1M001MFI
ALM, Radiator group
1 motor control
center fault
Radiator motor
overcurrent/shortcircu
it tripped
Check the overcurrent/shortcircuit
relay
VCA0_1M001AFI
ALM, Radiator group
1 Start/Stop fault
Radiator motor
activation is not
according to given
command
Check the functionality of the main
contactor, Check the wiring for
running information and start/stop
commands
VCA0_1M002MFI
ALM, Radiator group
2 motor control
center fault
Radiator motor
overcurrent/shortcircu
it tripped
Check the overcurrent/shortcircuit
relay
VCA0_1M002AFI
ALM, Radiator group
2 Start/Stop fault
Radiator motor
activation is not
according to given
command
Check the functionality of the main
contactor, Check the wiring for
running information and start/stop
commands
VCA0_1M003MFI
ALM, Radiator group
3 motor control
center fault
Radiator motor
overcurrent/shortcircu
it tripped
Check the overcurrent/shortcircuit
relay
VCA0_1M003AFI
ALM, Radiator group
3 Start/Stop fault
Radiator motor
activation is not
according to given
command
Check the functionality of the main
contactor, Check the wiring for
running information and start/stop
commands
VCA0_1M004MFI
ALM, Radiator group
4 motor control
center fault
Radiator motor
overcurrent/shortcircu
it tripped
Check the overcurrent/shortcircuit
relay
VCA0_1M004AFI
ALM, Radiator group
4 Start/Stop fault
Radiator motor
activation is not
according to given
command
Check the functionality of the main
contactor, Check the wiring for
running information and start/stop
commands
SOA0_1G001MFI
ALM, Turning gear
fault from PLC
Turning gear module
fault
Check the functionality of the main
contactor, Check the wiring for
running information and start/stop
commands
VDA0_1M001MFI
ALM, Water
preheater 1 control
center fault
Water preheater
overcurrent/shortcircu
it tripped
Check the overcurrent/shortcircuit
relay
VDA0_1M001AFI
ALM, Water
preheater 1
Start/Stop fault
Water preheater
activation is not
according to given
command
Check the functionality of the main
contactor, Check the wiring for
running information and start/stop
commands
Operating Troubles
34SG-200414-04
Содержание 41508
Страница 3: ......
Страница 12: ...Appendix B Welding Precautions 200147...
Страница 22: ...Fuel Lubricating Oil Cooling Water 34SG 200303 03...
Страница 29: ...A Ap pp pe en nd di ix x A A E En nv vi ir ro on nm me en nt ta al l H Ha az za ar rd ds s 2 20 00 03 32 21 1...
Страница 73: ...Maintenance Tools 32 9801...
Страница 115: ...Engine Block with Bearings Cylinder and Oil Sump 34SG 9701...