ARCHGARD LIMITED WARRANTY

 

TM 

 
This Limited Warranty is made by ARCHGARD INDUSTRIES LTD. hereinafter referred to as 
"ARCHGARD ". Archgard guarantees to the original consumer that the combustion chamber of its gas 
burning fireplaces will be free from defects in materials and workmanship under normal use and service, for 
a lifetime. Fabricated steel parts are covered for five year from date of purchase. Gas and electrical 
components are covered for one year from date of purchase. Paint, glass and trims are not covered. 
 
NOTE: Discoloration and some minor movement of certain parts is normal and is not a defect and therefore 

not covered under warranty. Overfiring of any appliance can cause serious damage and it is the 
responsibility of the installer to ensure that the appliance is firing as per rating plate. 

 
ARCHGARD disclaims any responsibility for the following actions, any of which will void the warranty: 

NOTE: SUCH ACTIONS MAY CAUSE A FIRE HAZARD. 

 *    Installation of any damaged fireplace or chimney components. 
 *    Modification of the gas fireplace or the vent system. 
 *    Improper positioning of the gas logs or the glass. 
 *    Installation and/or use of any components part not manufactured or 
      approved by ARCHGARD, not withstanding any independent testing 
      laboratory or other party approval of such component part or accessory. 
 
OBTAINING WARRANTY SERVICE 
To obtain warranty service, the consumer shall return the defective part to the original selling dealer 
transportation prepaid, along with the serial number of the appliance and proof of purchase. Any defective 
part, in our judgment, will be repaired or replaced at Archgard's discretion. The dealer must obtain approval 
from an authorized Archgard representative before any repairs are made. 
 
 

WARRANTY LIMITATION

 

 
THIS LIMITED WARRANTY IS MADE IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR 
IMPLIED AS TO QUALITY, MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE. 
 
The appliance is only warranted for the use as intended by the installation and operating instructions and 
local building codes. The warranty will not cover damage due to accident, misuse, abuse, alteration or 
improper installation.

 

This limited warranty is void unless the appliance is installed by a qualified installer, in accordance with the 
instructions furnished with the appliance. Some Provinces or States do not allow limitations on how long an 
implied warranty lasts, so the above limitation may not apply to the consumer. 
Any damages resulting from defects in this product, is limited to replacement of defective parts and does not 
include incidental and consequential expenses sustained in connection with the product. This warranty is 
limited to residential use only and gives the consumer specific rights. These rights may vary from State to 
State or Province to Province.

 

f i r e - p a r t s . c o m

Содержание northfire dvr36h

Страница 1: ...r s phone Follow the gas supplier s instructions If you cannot reach the gas supplier call the fire department PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLING AND OPERATING THE APPLIANCE WARNING...

Страница 2: ...tions 5 13 Operation Instructions 14 15 Maintenance 16 Trouble Shooting Instructions 17 18 Servicing 19 20 Important Information Form 21 Warranty 22 Parts and Accessories 23 Allowed Termination Locati...

Страница 3: ...ty Please read the manual carefully prior to installation and operation of the appliance Proper installation operation and maintenance of the appliance will provide you with many years of enjoyment CA...

Страница 4: ...orm with local code or current National Electrical code ANSI NFPA No 70 1987 in the US and in Canada the current Canadian Electrical Code CSA C22 1 HIGH ALTITUDE INSTALLATION When installing this appl...

Страница 5: ...CONTROL TOP LOUVERS GLASS DOOR APPLIANCE DIMENSIONS FRONT VIEW 36 1 4 23 1 2 37 3 4 TOP VIEW SIDE VIEW FRONT VIEW 3 1 2 Except for the vent connector locations the rear vented DVR36H and top vented D...

Страница 6: ...ble for venting See APPENDIX A ALLOWABLE TERMINATION LOCATIONS VENT TERMINATION 1 See ALLOWABLE TERMINATION LOCATIONS diagram page 24 to establish a suitable vent termination location 2 In heavy snowf...

Страница 7: ...nt 6 FRAMING DIMENSIONS 36 1 4 16 39 1 2 28 36 1 4 56 36 1 4 31 16 If more rigidity is required A stud may be added to the back of the top nailing flange after the fireplace is installed TERMINATION F...

Страница 8: ...Observe the venting chart given in this manual 5 Use a vent spacer between the inside and outside flex vents at every 3 ft intervals 6 Never slope horizontal running vents downwards 7 Maintain at leas...

Страница 9: ...stallations with short vents With taller vents the efficiency and flame characteristics will change Therefore an exhaust restrictor plate is provided by the manufacturer to preserve as much of the ori...

Страница 10: ...ravent locate the restrictor in the exhaust section fitting into the formed lip Restrictor Placement WARNING These restrictors are only to be installed in the vent system if the vent exceeds 7 in vert...

Страница 11: ...of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Failure to do so will damage the appliance s gas valve Such damage is not covered by the manufacturer s warran...

Страница 12: ...two buckle latches below the door Release the bottom buckles first then gently swing the door away from the fireplace and lift it off the top hooks Keep the door pressed against the appliance while r...

Страница 13: ...om obstructing the burner ports WARNING Do not place the lava rocks or the embers directly on the burner ports fire explosion or excessive carbon monoxide CO may result causing property damage persona...

Страница 14: ...eplace and into the bottom of the gas fireplace Be sure to connect a grounding wire to the side of gas fireplace Use any screw hole on the side for this purpose Slide the thermal snap switch into the...

Страница 15: ...e appliance area for gas Be sure to smell next to the floor because some gases are heavier than air and will settle on the floor IF YOU SMELL GAS follow the instruction on the front cover of this manu...

Страница 16: ...tly and turn control knob counterclockwise 4 to PILOT position depress control knob and light pilot by repeatedly pressing the sparker Venting of air may take place at the pilot prior to the flow of f...

Страница 17: ...e outside the house wearing a dust mask The logs are very fragile take care not to break them After cleaning the logs must be replaced as per the instructions in this manual When replacing glass door...

Страница 18: ...as valve may be defective Pilot will not remain on after being lit 1 Press the control knob all the way in 2 Hold the control knob in for a longer period of time 3 If you are trying to re light the pi...

Страница 19: ...primary air by opening the primary air shutter 2 Check for proper placement of the logs and branches See that section in the instruction manual 3 Check for obstruction of the burner ports by the ember...

Страница 20: ...with a screwdriver Rotate air shutter with a flat tip screw driver The primary air opening size can be easily seen with a flashlight Tighten the air shutter set screw after adjustment CAUTION Adjust...

Страница 21: ...ssembly plate to the appliance Gently lift the assembly up and tilt the back up to clear the front of the valve from the opening Replacing the assembly is the reverse of the above instructions Disconn...

Страница 22: ...HONE NUMBER COMPANY NAME ADDRESS PHONE NUMBER APPLIANCE MODEL NUMBER NORTHFIRE DVR36H DVT36H SERIAL NUMBER GAS TYPE NATURAL GAS LPG VALVE TYPE SIT 820 DATE PURCHASED INSTALLATION INSTALLER NAME DATE I...

Страница 23: ...part or accessory OBTAINING WARRANTY SERVICE To obtain warranty service the consumer shall return the defective part to the original selling dealer transportation prepaid along with the serial number...

Страница 24: ...0007 BURNER 836 0050 ORIFICE CAP NG 44 DMS 301 0057 ORIFICE CAP LP 55 DMS 301 0060 LOG SET 3 Piece 310 0019 5 FT VENT TERMINATION KIT TVK 2 VENT TERMINATION TK 1 4 x 5 FT ALUMINUM FLEX PIPE 312 0014 7...

Страница 25: ...24 24 fire parts com...

Страница 26: ...___________________ Telephone ______ ______ _________ Dealer s Name Address ______________________________________________________ ______________________________________________________ Installer s Na...

Отзывы: