19
substances so that the device warranty does not lose its validity
otherwise it will have a negative effect on the operation of the boiler.
We comply with the standards laid down in the standards for domestic
water and heating installations in order to prevent the accumulation of
lime in the heating installation and therefore the erroneous operation
of the installation.
Preventive water treatment procedure for cast aluminium
heat exchange
The following descriptions describe the quality of water required
for aluminium heat exchangers. In order to obtain the required heat
transfer, the installation water must be of good quality. Parameters such
as PH, hardness, conductivity, oxygen, flux residues, oil residues and
corrosion products due to installation can have negative effects on the
heat exchanger.
Before filling (old and new) the installation, it should be thoroughly
rinsed in accordance with EN 14336 with clean running water from the
faucet.
For water treatment Warmhaus only permits the products listed below.
For the protection and long-term use of the heat exchanger,
Warmhaus always specifies the following criteria for the quality of
the installation water and the filling water:
• PH should be kept between 6.5 and 8.5.
• The maximum permissible chlorine content for the aluminium heat
exchanger is 250 mg/litre.
2.11. MOUNTING RULES FOR HYDRAULIC
INSTALLATION
2.11.1. Structure of Heating Water
Caution:
Before making the connection to the boiler, make
sure that any residues in the main heat exchanger (pipes,
heating appliances, etc.) are removed using solvents or similar
150 cm
Min.
30 cm
The room thermostat should be installed at
a distance of 1.25 to 1.5 m from the floor.
It should be at least 30 cm away from the open
door and window edges to air flow.
COLD
WATER
System Pump
Electrical
Panel
Boiler panel and Electrical
Panel connection for
System Pump
3 x 1.0 mm
2
Timer/Room
Thermostat
2 x 1.0 mm
2
GAS LINE
1.Zone
Timer/Room
Thermostat
Outside
Air Sensor
2 x 1.0 mm
2
FLUE
Pump
cable
3 x 1.0 mm
2
1. Boiler
2. Gas Safety Solenoid Valve
3. Ball Valve
4. Gas Filter
5. Vibration İsolator
6. Condensate Siphon and Drainage Line
7. Check Valve
8. Boiler (Return) Pump
9. Automatic Air Purge Valve
10. Sediment-Dirt-Air Separator
11. Manometer
13. Hydraulic Separator
14. Sediment-Dirt Separator
15. Heating System Steam Water Collector
16. Heating System Return Water Collector
17. Heating System Pump
18. Heating System
19. Pressure Reducer
27. Expansion Tank
28. Filter
29. Timer/Room Thermostat
30. Boiler Electrical Panel
31. Outside Air Sensor
Figure 2.31
Single Boiler and 1 High Temperature Zone Connection Schema
Figure 2.30
True and False Positions of Room Thermostat