34
7
INFO 4:
Display of Plant Probe temperature sensor OR AUX sensor temperature ( selectable by Par=52).
Value is available ONLY / WHEN sensor connected. IF the sensor not available OR not connected the value
shown as " - - "
8
INFO 5:
Display of fume temperature sensor.
Value is available ONLY / WHEN sensor connected. IF the sensor not available OR not connected the value
shown as " - - "
9
INFO 6:
Display of heating flow ( CH ) SET temperature ZONE 1.
Value is available ONLY / WHEN sensor connected. IF the sensor not available OR not connected the value
shown as " - - "
10
INFO 7:
Display of heating flow ( CH ) SET temperature ZONE 2.
11
INFO 8:
Display of ionisation current (
μ
A).
12
INFO 9:
Display of fan speed in rpm x100. (ie. 33 x 100 = 3300 rpm)
13
INFO 10:
Display of number of hours of the burner in hour x 100 (ie. 6.8 x 100 = 6800 hours)
14
INFO 11:
Display of number of times the burner has ignited x 1000
(ie. 23 x 1000 = 23.000 times)
15
INFO 12:
Display of number of total number of errors.
(ie. 18 = 18 times)
16
INFO 13:
Display of number of INSTALLER parameters ( Par 1-49) accessed.
Counter-installer.
(ie. 15 = Parameter menu Par 1 - 49 has been 15 times activated)