2.2.1. Sizes and Connections
120
615
103,4
195
790
153,4
102
102
411
103,4
153,4
3
1
2
4
5
6
18
Gas İnlet
G 1"
CH Return
G1 1/2"
CH Flow
G1 1/2"
CONDANSATE
DRAIN
322
164
148
261
305
330
498
330
305
261
148
164
720
54
615
195
507
3
1
2
4
5
6
Gas İnlet
G 1"
CH Return
G1 1/2"
CH Flow
G1 1/2"
CONDANSATE
DRAIN
322
164
148
261
305
330
54
2.3. MOUNTING RULES FOR BOILER
2.3.1. General Rules for Places for Mounting The Boiler
There is no ventilation limitation for places where the hermetic (C
type) boiler is mounted (the devices can be mounted regardless of
the volume and ventilation form of the room). In addition, it can be
mounted in partially protected areas such as balconies and terraces
provided that it is in the protective cabin and necessary precautions
are taken against freezing in the installation water. However, the
installation requirements of the local gas company in the area to be
mounted must also be taken into consideration, so be careful about
the mounting locations for over a certain capacity!
The boiler should be mounted firmly on the building wall. A flexible
connection element must be used between the boiler and the gas
line. Flexure lengths to be used on A, B and C type devices shall not
exceed the permissible limits from local gas companies. The chimney
outlets of the hermetic boilers must be connected directly to the
outdoor with open air circulation. The gas outlet conditions of waste
gas installation of these devices should be in accordance with the
rules set out in TS 12514 standard (positions of the pipe outlets in
relation to various forms, vertical, horizontal minimum distances, cross-
sectional areas of the ducts if connected to ducts).
2.3.2. Places Where Hermetic Boiler Cannot Be Mounted
• To the stairwells of buildings
• To the common spaces of the buildings which are open to general
use, air wells and day spaces, to the attic, to the under the roof, to
emergency exit doors, and similar places such cellar, hall etc.
• To the yards between buildings
• To narrow eaves gaps
• On chimney walls,
• To closed balconies,
• To open balconies except for being in a cabin and permitted by
device company and local gas company),
• Underneath the protruding parts of the structure which prevent the
outler of waste gas,
• To places where can be exposed to direct wind pressure
• It is forbidden to mount hermetic boilers (type C) in openings that
provide fresh air to other units!
2.3.3. Wall Mounting of Boiler and Selection of Mounting Location
• It must be checked and guaranteed wall-mounting of boiler is sound
and safe.
Figure 2.7
Boiler sizes and connections
Viwa 90 / Viwa 115
Viwa 125 / Viwa 150
Warmhaus Viwa 125 / Viwa 150
1) Heater Return Line
2) Sediment-Air Separator Discharge Line
3) Condensing Water Discharge Line
4) Gas Inlet Line
5) Heater Stream Line
6) Cable Outlets
7) Waste Gas Outlet Connection (Ø100mm)
8) Fresh Air Inlet Connection (Ø150 mm)
9) Fresh Air Measurement Point
10) Waste Gas Measurement Point