8

warmhaus.com

2.  USER'S SECTION

2.1.  GENERAL WARNINGS FOR USER 

2.1.1. Use of Combi Boiler

If a gas odour is available in the environment, close home entrance line 
and gas valves of your combi boiler or close the LPG tank valve or bottle 
valve if bulk gas is used. Do not shut on-off electricity buttons and do not 
do anything those may create sparks. Call the gas company or Authorized 
Service. (See 1.4 GAS LEAKAGES, Page 6)

First start should be performed by the Warmhaus Authorized Service for 
your safety and preventing void warranty scope. Our Authorized Service will 
give you required information about use of combi boiler after performing 
initial controls of your combi boiler and starting for the first time. 

Perform below given controls prior to starting to use:

•  Ensure that radiator/heating system, tap water and gas valves located 

under your combi boiler are open, the radiator installation pressure is 
between 1 - 1,5 bar on the manometer located under the Combi Boiler and 
system air is discharged,

•  Gas is available in your gas line (you can control by igniting one of your 

gas ovens),

•  Combi Boiler electrical fuse is open,
•  No flammable materials and products are available near to the Combi 

Boiler,

•  Exhaust gas flue set output is not blocked,
•  If a room thermostat or control device is connected, ensure that it is at 

ON position.

If you will shut-off the combi boiler for a long period, perform below 

written operations:

•  Discharge the radiator installation water not containing anti-freeze,
•  Close combi boiler electrical fuse, gas valve, radiator and tap water valves!

If you will shut-off the combi boiler for a short period, perform below 

written operations:

•  Do not close combi boiler electrical fuse, gas valve, radiator and tap water 

valves!

• Leave the Combi Boiler at Summer position and activate its Frost 

Protection function,

Shut-off the combi boiler during maintenance and repair operations to 
be performed around exhaust gas discharge flues. After operations are 
completed, have the combi boiler controlled by Warmhaus Authorized 
Service.

Follow below given main rules:

• Do not clean external frame of combi boiler while combi boiler is 

functioning and do not use easily flammable materials.

•  Do not hold the combi boiler with wet hands or feet; also without shoes 

and with bare feet.

•  Do not pick electricity cables.
•  In case cables are damaged, shut-off the combi boiler and fuse switches 

and do not use the combi boiler.

•  Electrical cables of combi boiler and its accessories should have replaced 

by the Authorized Service.

•  Do not expose the hung combi boiler to direct vapour those may arise 

from cooking places.

•  Prevent use of combi boiler by children and inexperienced persons.

Содержание ENERWA

Страница 1: ......

Страница 2: ......

Страница 3: ......

Страница 4: ......

Страница 5: ......

Страница 6: ...iately evacuate the place with gas odour Natural Gas Emergency Line from your neighbour or another suitable place Do not make any intervention on installation Never close culverts ensuring discharge o...

Страница 7: ...7 warmhaus com...

Страница 8: ...blocked If a room thermostat or control device is connected ensure that it is at ON position If you will shut off the combi boiler for a long period perform below written operations Discharge the radi...

Страница 9: ......

Страница 10: ...ockwise or decreases when rotated counter clockwise The adjusted value shall be confirmed after flashing for 4 5 seconds after releasing the button and continues to display the temperature value in th...

Страница 11: ......

Страница 12: ......

Страница 13: ......

Страница 14: ......

Страница 15: ...heck if problem removed 2 Check boiler central heating valves are open if they are closed open all 3 Check all radiator valves are open if they are closed open minimum 3 meters of radiator must be ope...

Страница 16: ...E 42 Buttons anomaly Boiler does not work E42 error code flashing on the screen Wrong parameters settled on TsP menu 1 Call For service E 43 Opentherm communication error Boiler does not work E43 err...

Страница 17: ...lokage on flue or wrong flue Electrode position Cabling disconnections Combustion calibration Electronic board Gas valve failure 1 Reset Restart boiler 2 Call for authorised service E 92 Air compensat...

Страница 18: ...y valve discharge should be connected to a discharge funnel Otherwise safety valve shall be activated and manufacturer shall not be responsible due to water discharge to the place of device 0 3 2 1 0...

Страница 19: ...over time you must at least execute maintenance operations on a yearly basis in compliance with what is stated in the relative point at annual check and maintenance of the appliance in compliance with...

Страница 20: ......

Страница 21: ...lgesi Park Cadde No 10 10 05 2016 www warmhaus com tr Par a Ad Nil fer BURSA TURKEY Malzeme Tarih Date izen Drawn TAR H REV NO A IKLAMA Kontrol Approved Onay Drawn aut REV Z YAPAN All rights reserved...

Страница 22: ......

Страница 23: ......

Страница 24: ......

Отзывы: