Error

Code

Description of the Error

Malfunction

Probable Cause

Solution(s)

E 80

Problem on electronic gas

valve driver

Boiler does not work,

E80 error code flashing on

the screen

> Electronic board

> Gas valve failure

1-) Reset & Restart boiler

2-) Call for authorised service.

E 81

Lock-out for combustion

problem at starting (1)

Boiler does not work,

E81 error code flashing on

the screen

> Strong flue blokage

> Combustion problem

> Wrong flue

> Gas inlet pressure

> Aging or rust on the electrode

> Recirculation on fluegas path

> Electrode position

> Combustion calibration

1-) Reset & Restart boiler

2-) Call for authorised service.

E 84

Capacity reduction for

detected (supposed) low 

gas inlet pressure

Boiler operates at limited 

capacity, E84 error code 

flashing on the screen

> Gas inlet pressure

> Combustion problem

1-) If there is strong wind (ie.wind storm) wait until the wind storm 

stop then RESET the boiler

2-) IF problem persist Call for authorised service

Attention: Only authorised service must perform Au-To calibration

E 87

Problem on electronic gas

valve circuit

Boiler does not work,

E87 error code flashing on

the screen

> Cabling disconnections

> Gas valve failure

1-) If there is strong wind (ie.wind storm) wait until the wind storm 

stop

then RESET the boiler

2-) IF problem persist Call for authorised service

Attention: Only authorised service must perform Au-To calibration

E 88

Fault of electronic gas 

valve managing circuit

Boiler does not work,

E88 error code flashing on

the screen

> Cabling disconnections

> Gas valve failure

1-) Reset & Restart boiler

2-) Call for authorised service.

E 89

Problem on combustion

feedback signal

Boiler does not work,

E89 error code flashing on

the screen

> Aging or rust on the electrode

> Recirculation on fluegas path

> Blokage on flue or wrong flue

> Electrode position

> Cabling disconnections

> Combustion calibration

> Electronic board

> Gas valve failure

1-) Reset & Restart boiler

2-) Call for authorised service.

E 90

Unable to regulate

combustion

Boiler does not work,

E90 error code flashing

on the screen

> Aging or rust on the electrode

> Recirculation on fluegas path

> Blokage on flue or wrong flue

> Electrode position

> Cabling disconnections

> Combustion calibration

> Electronic board

> Gas valve failure

1-) Reset & Restart boiler

2-) Call for authorised service.

E 92

Air compensation active

Boiler does not work,

E92 error code flashing

on the screen

> Possible wind precence

> Aging or rust on the electrode

> Recirculation on fluegas path

> Blokage on flue or wrong flue

> Electrode position

> Combustion calibration

> Min power adjustment

1-) Reset & Restart boiler

2-) Call for authorised service.

E 93

Unable to regulate

combustion (temporarily)

Boiler does not work,

E93 error code flashing

on the screen

> Aging or rust on the electrode

> Recirculation on fluegas path

> Blokage on flue or wrong flue

> Electrode position

> Combustion calibration

> Gas valve failure

> Electronic board

1-) Reset & Restart boiler

2-) Call for authorised service.

E 94

Possible low gas pressure

or exhaust recirculation

Boiler does not work,

E94 error code flashing

on the screen

> Gas inlet pressure LOW

> Recirculation on fluegas path

> Blokage on flue or wrong flue

> Aging or rust on the electrode

> Electrode position

> Combustion calibration

> Gas valve failure

> Electronic board

1-) Reset & Restart boiler

2-) Call for authorised service.

Attention: 

Only authorised service must perform Au-To calibration

E 95

Intermittent combustion

value

Boiler does not work,

E95 error code flashing

on the screen

> Harness on electrode and earth

> Aging or rust on the electrode

> Electrode position

> Combustion calibration

1-) Reset & Restart boiler

2-) Call for authorised service.

E 96

Flue or air suction way

blockage

Boiler does not work,

E96 error code flashing

on the screen

> Blokage on flue

> Blokage on air suction path

1-) Reset & Restart boiler

2-) Call for authorised service.

E 98

SW error, board start-up

error fault

Boiler does not work,

E98 error code flashing

on the screen

> Boiler software problem

1-) Reset & Restart boiler

2-) Call for authorised service.

E 99

Generic fault

Boiler does not work,

E99 error code flashing

on the screen

> Boiler electronic hardware

problem

1-) Reset & Restart boiler

2-) Call for authorised service.

(1) Call the Authorized Service if failure continues.

(2) 81 numbered failure corresponds any blocking in the exhaust gas pipe. In such case, you should consult the authorized service technician before re-starting the combi boiler.

Содержание ENERWA

Страница 1: ......

Страница 2: ......

Страница 3: ......

Страница 4: ......

Страница 5: ......

Страница 6: ...iately evacuate the place with gas odour Natural Gas Emergency Line from your neighbour or another suitable place Do not make any intervention on installation Never close culverts ensuring discharge o...

Страница 7: ...7 warmhaus com...

Страница 8: ...blocked If a room thermostat or control device is connected ensure that it is at ON position If you will shut off the combi boiler for a long period perform below written operations Discharge the radi...

Страница 9: ......

Страница 10: ...ockwise or decreases when rotated counter clockwise The adjusted value shall be confirmed after flashing for 4 5 seconds after releasing the button and continues to display the temperature value in th...

Страница 11: ......

Страница 12: ......

Страница 13: ......

Страница 14: ......

Страница 15: ...heck if problem removed 2 Check boiler central heating valves are open if they are closed open all 3 Check all radiator valves are open if they are closed open minimum 3 meters of radiator must be ope...

Страница 16: ...E 42 Buttons anomaly Boiler does not work E42 error code flashing on the screen Wrong parameters settled on TsP menu 1 Call For service E 43 Opentherm communication error Boiler does not work E43 err...

Страница 17: ...lokage on flue or wrong flue Electrode position Cabling disconnections Combustion calibration Electronic board Gas valve failure 1 Reset Restart boiler 2 Call for authorised service E 92 Air compensat...

Страница 18: ...y valve discharge should be connected to a discharge funnel Otherwise safety valve shall be activated and manufacturer shall not be responsible due to water discharge to the place of device 0 3 2 1 0...

Страница 19: ...over time you must at least execute maintenance operations on a yearly basis in compliance with what is stated in the relative point at annual check and maintenance of the appliance in compliance with...

Страница 20: ......

Страница 21: ...lgesi Park Cadde No 10 10 05 2016 www warmhaus com tr Par a Ad Nil fer BURSA TURKEY Malzeme Tarih Date izen Drawn TAR H REV NO A IKLAMA Kontrol Approved Onay Drawn aut REV Z YAPAN All rights reserved...

Страница 22: ......

Страница 23: ......

Страница 24: ......

Отзывы: