2.4. RECOMMENDATIONS FOR ECONOMICAL USE OF 

COMBI BOILER

Your combi boiler is adjusted at ECO mode for economic use, we recommend 
not to change.

Correct Capacity Selection

Heat loss calculation of the combi boiler location should be made correctly 
and combi boiler capacity should comply with this calculation. Devices not 
having adequate capacity shall give late responses to heating requests, 
devices with higher capacity may cause discomfort and more fuel 
consumption as they more frequently opened and closed. Therefore, combi 
boiler capacities should be selected according to the place used. 

Insulation

Insulation of your building is the most important item reducing the heat 
loss and gas consumption. However, as your combi boiler has the highest 
thickness insulation of its class, heat loss is minimized.

Radiators

Ensure balancing our pressure distribution of your radiator installation within 
the house by making reduction adjustments from radiator valves. Placing 
furnitures in front of radiators prevents air circulation and causes discomfort 
and more fuel consumption. Reducing radiator valves of rooms not used for 
a long period or if thermostatic radiator valve is used, bringing to the lowest 
position then, closing room doors will provide saving. 

Domestic Hot Water

Always adjust the domestic hot water temperature as (38~42 °C). Adjustment 
of temperature adjuster as low ensures a considerable power saving. In 
addition, high domestic hot water temperatures cause strong calcification 
and that negatively affects operation of the device (for instance, longer 
heating periods, less flow rate).

Thermostatic Radiator Valves 

You can both acquire savings and comfort by balancing the heat distribution 
among the house by using Thermostatic Radiator Valves.

Room Thermostats 

Your combi boiler will operate more economically as you will have the 
chance to adjust requested room temperature according to comfort and 
economy timings via room thermostats. Thus, you can adjust temperature 
of your room as you wish, and also you can acquire approximately 6% power 
saving with every degree of temperature decrease.

Ventilation

Do not leave windows slightly open for ventilating room/rooms. In such case, 
continuous heat loss will occur and not having any certain improvement in 
the room air.

Fully opening windows for a short period provides a better result. Bring 
thermostatic radiator valves to lowest position when ventilating rooms.

Cleaning And Maintenance
Attention:

 to preserve the boiler's integrity and keep the safety features, 

performance and reliability, which distinguish it, unchanged over time, you 
must at least execute maintenance operations on a yearly basis in compliance 
with what is stated in the relative point at “annual check and maintenance 
of the appliance”, in compliance with national, regional, or local standards 
in force. 

We recommend stipulating a yearly cleaning and maintenance contract with 
an authorised local firm.

2.5.  ISSUES REQUIRED TO BE TAKEN INTO 

CONSIDERATION FOR WARRANTY CONDITIONS

This warranty given by WARMHAUS does not cover elimination of failures 
arising from abnormal use of the product and also out of the warranty scope 
for below given situations

1. 

Damages and failures occurring in devices which are not first started by 
Warmhaus Authorized Services,

2.

 Damages and failures arising from use of the product contrary to items 

given in User's Manual and using out of its intended purpose.

3.

 Damages and failures arising from wrong type selection,

4.

 Damages and failures arising from maintenance and repairs performed by 

persons other than our Authorized Services,

5.

 Damages and failures occurring due to transportation, unloading, loading, 

storing, external physical (Crushing, scratches, fractures) and chemical 
factors following delivery of the Product,

6.

 Damages and failures arising from fire and lightning,

7.

 Damages and failures arising from false fuel use and fuel characteristics,

8.

 Low or excessive voltage; unearthed socket usage;

9.

 Damages and failures arising from faulty electricity installations,

10.

Damages and failures arising from failing to perform timely annual  

maintenance and cleaning,

11.

 Defined periodical maintenance operations by our Authorized Services,

12.

Damages and failures those may occur in the device or usage area due to 

other products and accessories used in a system with the device subject 
to the Warranty,

13.

Damages and failures arising from frost/icing or occurring due to using in 

the outdoor places (open balcony, etc.).

14.

Altering the Registry Label and Warranty Certificate,

15.

Damages and failures arising from using water out of the water values 

defined in device user's guide,

Elimination of above mentioned failures shall be performed against payment.

Our distinguished customer,
we believe the importance of providing good products to you as well as 
rendering good services.

Recommendations and Data to be Followed:
1.

 When first start of your combi boiler is done, please keep the technical 

service document given by the Aythorized Service and a copy of device 
invoice and the Warranty Document approved by your Authorized Dealer.

2.

 Use your product according to principles of installation and operation 

guide.

3.

 Keep the "SERVICE DOCUMENT" if received from your service technician 

following the service taken. The Service Document will be beneficial for 
you in any problems those may occur in your device in the future.

Содержание ENERWA

Страница 1: ......

Страница 2: ......

Страница 3: ......

Страница 4: ......

Страница 5: ......

Страница 6: ...iately evacuate the place with gas odour Natural Gas Emergency Line from your neighbour or another suitable place Do not make any intervention on installation Never close culverts ensuring discharge o...

Страница 7: ...7 warmhaus com...

Страница 8: ...blocked If a room thermostat or control device is connected ensure that it is at ON position If you will shut off the combi boiler for a long period perform below written operations Discharge the radi...

Страница 9: ......

Страница 10: ...ockwise or decreases when rotated counter clockwise The adjusted value shall be confirmed after flashing for 4 5 seconds after releasing the button and continues to display the temperature value in th...

Страница 11: ......

Страница 12: ......

Страница 13: ......

Страница 14: ......

Страница 15: ...heck if problem removed 2 Check boiler central heating valves are open if they are closed open all 3 Check all radiator valves are open if they are closed open minimum 3 meters of radiator must be ope...

Страница 16: ...E 42 Buttons anomaly Boiler does not work E42 error code flashing on the screen Wrong parameters settled on TsP menu 1 Call For service E 43 Opentherm communication error Boiler does not work E43 err...

Страница 17: ...lokage on flue or wrong flue Electrode position Cabling disconnections Combustion calibration Electronic board Gas valve failure 1 Reset Restart boiler 2 Call for authorised service E 92 Air compensat...

Страница 18: ...y valve discharge should be connected to a discharge funnel Otherwise safety valve shall be activated and manufacturer shall not be responsible due to water discharge to the place of device 0 3 2 1 0...

Страница 19: ...over time you must at least execute maintenance operations on a yearly basis in compliance with what is stated in the relative point at annual check and maintenance of the appliance in compliance with...

Страница 20: ......

Страница 21: ...lgesi Park Cadde No 10 10 05 2016 www warmhaus com tr Par a Ad Nil fer BURSA TURKEY Malzeme Tarih Date izen Drawn TAR H REV NO A IKLAMA Kontrol Approved Onay Drawn aut REV Z YAPAN All rights reserved...

Страница 22: ......

Страница 23: ......

Страница 24: ......

Отзывы: