70
Message / alert
DESCRIPTION AND ACTIONS
There is not enough water in the tank to perform a cycle.
Fill the water tank as requested.
The used water tank is full.
Drain the water tank as requested.
The door must be locked, but you didn't close it.
Close the door so it can be locked.
The clean water quality is bad (conductivity between 15 and 50
µS/cm).
You may run a cycle but the water must be replaced
soon, otherwise the unit will automatically lock-out to
prevent damage.
The clean water quality is very bad (conductivity more than 50
µS/cm).
Running a cycle is inhibited to prevent damage. Replace
the clean water.
These are pre-alerts advising that one of the consumables has to be
replaced within a small number of cycles.
Press CONFIRM if you have the consumable available for
replacement.
Press NO if you don't have the consumable in stock and
must order one.
In this case, the pre-alert will appear again after some
cycles.
See Chapter 8 – MAINTENANCE
This pre-alert advises you that the target of 4000 cycles is close and
the relevant maintenance step is to be scheduled.
Contact your Technical Service
Messages and alerts
NOTE: for any error not listed in this table, call technical service.
. . . . . .
. . . . . .
. . . . . .
. . . . . .