APPENDIX 7. Water quality
APPENDIX 7. Water quality
APPENDIX 7. Water quality
APPENDIX 7. Water quality
The use of water with a conductivity greater than 15µS/cm may affect the sterilization process and damage the sterilizer.
The use of water with a conductivity greater than 50µS/cm, or not complying with the specifications in the table above, may strongly affect
the sterilization process and seriously damage the sterilizer.
The manufacturer’s warranty is void if the sterilizer was used with
The manufacturer’s warranty is void if the sterilizer was used with
The manufacturer’s warranty is void if the sterilizer was used with
The manufacturer’s warranty is void if the sterilizer was used with water containing contaminant or chemical levels
water containing contaminant or chemical levels
water containing contaminant or chemical levels
water containing contaminant or chemical levels exceeding
exceeding
exceeding
exceeding
those listed in the table
those listed in the table
those listed in the table
those listed in the table above.
above.
above.
above.
FEED WATER SPECIFICATIONS
FEED WATER SPECIFICATIONS
FEED WATER SPECIFICATIONS
FEED WATER SPECIFICATIONS
Contaminants/minerals/qualities
Contaminants/minerals/qualities
Contaminants/minerals/qualities
Contaminants/minerals/qualities
Value/Specification
Value/Specification
Value/Specification
Value/Specification
Evaporate residue
< 10 mg/l
Silicon oxide, SiO
2
< 1 mg/l
Iron
< 0,2 mg/l
Cadmium
< 0,005 mg/l
Lead
< 0,05 mg/l
Heavy metals (excl. iron, cadmium, lead)
< 0,1 mg/l
Chloride
< 2 mg/l
Phosphate
< 0,5 mg/l
Conductivity (at 20
°
C)
< 15 µs/cm
pH value
5 - 7
Appearance
colorless, clean, free from sediment
Hardness
< 0,02 mmol/l
Chemical additives
No
No
No
No chemicals
chemicals
chemicals
chemicals or
or
or
or additives
additives
additives
additives must
must
must
must be
be
be
be added
added
added
added to
to
to
to the
the
the
the water
water
water
water used
used
used
used for
for
for
for the
the
the
the steam
steam
steam
steam sterilization
sterilization
sterilization
sterilization process
process
process
process, even if
they are specifically claimed for use in steam generators, or for steam production, or as additives for
sterilization, disinfection, cleaning or corrosion protection.
LINA MB sterilizers use distilled or demineralized water to generate steam for the sterilization process.
The table below lists the maximum content of minerals and the specifications for the water used for steam sterilization (see EN13060 APPENDIX C).