31
Customization of cycle parameters
Customization of cycle parameters
Customization of cycle parameters
Customization of cycle parameters
MENU
MENU
MENU
MENU
SUB
SUB
SUB
SUB----MENU
MENU
MENU
MENU
WHAT IT DOES AND HOW TO SET IT
WHAT IT DOES AND HOW TO SET IT
WHAT IT DOES AND HOW TO SET IT
WHAT IT DOES AND HOW TO SET IT
(*)
(*)
(*)
(*)
Sets the cycle as the default cycle,
Sets the cycle as the default cycle,
Sets the cycle as the default cycle,
Sets the cycle as the default cycle, means it will appear first on the start screen. After pressing OK, press OK on YES to set the cycle as
the default cycle (the other cycles will be automatically set to NO); press BACK to exit without saving.
(*)
(*)
(*)
(*)
Unhides
Unhides
Unhides
Unhides/hides a cycle.
/hides a cycle.
/hides a cycle.
/hides a cycle. Once a cycle is hidden, it will no longer be visible in the menus and thus it will be impossible to launch it.
After pressing OK you can scroll between YES and NO with the UP and DOWN buttons. Press OK on YES to hide the cycle, press OK on NO to
unhide it, press BACK to exit without change.
(*)
(*)
(*)
(*)
Sets
Sets
Sets
Sets the plateau temperature.
the plateau temperature.
the plateau temperature.
the plateau temperature.
After pressing OK, an asterisk will appear near the current value, indicating that it can be changed
by pressing UP or DOWN. After programming the desired value, press OK to confirm or BACK to exit
without saving.
(*)
(*)
(*)
(*)
Sets
Sets
Sets
Sets the
the
the
the duration
duration
duration
duration of
of
of
of the plateau
the plateau
the plateau
the plateau phase
phase
phase
phase....
(*)
(*)
(*)
(*)
Sets
Sets
Sets
Sets the
the
the
the duration
duration
duration
duration of
of
of
of the
the
the
the drying
drying
drying
drying phase
phase
phase
phase....
(*) The parameters that you can actually change depend on the country of use, the model of the sterilizer and the access level.
After selecting a cycle, press UP or DOWN until the SETUP option appears and confirm (OK).
Scroll the sub-menu options by pressing UP or DOWN (the current value is displayed) and
follow the instructions in the table below.
You can customize a cycle program by setting certain parameters according to your own sterilization protocol.
The parameters you can set are the drying time, the plateau time, and the plateau temperature (see note(*) below).
Changing the plateau time and temperature
Changing the plateau time and temperature
Changing the plateau time and temperature
Changing the plateau time and temperature
It is strongly recommended not to decrease neither the plateau time nor the plateau temperature, as these are sterilization
parameters that shall comply with stringent requirements of legal, regulatory and scientific nature.
Changing the drying time
Changing the drying time
Changing the drying time
Changing the drying time
The duration of the drying time can be increased or decreased according to the characteristics of the load. When changing the
drying time, ensure that the load is always dry at the end of a sterilization cycle in order to avoid wicking of moisture and,
potentially, microorganisms from hands, gloves or environmental surfaces.