Rev. 1.4
Assembly Instructions
– Spray Valve SMS-11
Page 17 o
f
28
Walther Systemtechnik GmbH
– D 76726 Germersheim
Telefon: +49 (0)7274-7022-0 Telefax: +49 (0)7274-7022-91
http://www.walther-2000.de
8 Taking out of Service
CAUTION
Remove pressure from all connections and disconnect supply of energy and material.
Follow the operating and maintenance instructions!
Danger of accidents and hazard for environment. Do not spill medium. Medium will be
properly disposed of (hazardous waste).
8.1 Short Interruption
A short interruption (15 min or more) has to be followed by a clean spraying.
8.2 Long-term Interruption
The following has to be observed for a long-term interruption of the device/machine:
Remove pressure from supply lines.
Loosen retaining ring
(1)
and remove air cap
(2)
.
Unscrew nozzle
(3)
and clean with a special thinner and a soft cloth. Make sure that not fibers remain
on the nozzle tip.
8.3 Shutdown of Device
The following is important for a shutdown of the machine / device:
Remove pressure from supply lines and disconnect.
Clean spray valve with a special thinner.
Properly dispose of the medium.
8.4 Disposal
CAUTION
Any disposal of the device will be performed in accordance with the guiding rules and
regulations on waste disposal of the local authorities. Lubricants are considered hazardous
waste!