40ea manual
- 33 -
Tank placement
1. The fuel tank should always be placed below the base of the device. (The fuel surface level must be below the
device.) When the fuel level is above the base, the solenoid valve 30017 must be installed on the tank-side end of the
hose.
2. The fuel tank can be placed in the base housing 4031, or outside it, for exam¬ple, in the foundations of the house or
a suitable protective box. Protect the tank and the fuel hose from direct sunlight.
3. The fuel hose lead-through must be shielded by a metal cover pipe.
4. The standard length of the fuel hose is 4 m. It can be extended with a 2 m extension hose, which gives a total length
of 6 m. Connect the hoses with bayonet couplings, which are twisted together.
Содержание 40ea
Страница 4: ...40ea manual 3 Conformity with ecodirective Wallas 40EA conforms with ecodirective...
Страница 11: ...40ea manual 10 Electrical connections of the device...
Страница 12: ...40ea manual 11...
Страница 13: ...40ea manual 12...
Страница 19: ...40ea manual 18 Turn the heater of by sending 1234 R10...
Страница 27: ...40ea manual 26 Wall lead through section view...
Страница 30: ...40ea manual 29 Measurements for the hole are 516x328mm...
Страница 32: ...40ea manual 31 Heater fuel connections Suitable fuels Wallas Marin recommends to use 100 HVO Diesels...