![background image](http://html1.mh-extra.com/html/wallas/40ea/40ea_manual_3234513020.webp)
40ea manual
- 19 -
Ask the status of the heater by sending:
"1234 S1"
Remote will reply with information of the situation.
Rel 1= Heater on/off
Temp2= room temperature
Volt= Battery voltage.
It takes 15 seconds from the moment of entering the command to update the S4
data. Therefore it is recommended that the ON/OFF OFF/TEMPERATURE com-
mands are sent separately with an interval of at least 15 seconds.
“S” status
This command provides an overview of the status of the 4430 unit. The 4430 unit sends the status data as a text
message to the GSM phone of the person sending the enquiry.
An example of the data received in response to the “1234 S4” command:
Response text message:
Wallas: Heater is off.
Содержание 40ea
Страница 4: ...40ea manual 3 Conformity with ecodirective Wallas 40EA conforms with ecodirective...
Страница 11: ...40ea manual 10 Electrical connections of the device...
Страница 12: ...40ea manual 11...
Страница 13: ...40ea manual 12...
Страница 19: ...40ea manual 18 Turn the heater of by sending 1234 R10...
Страница 27: ...40ea manual 26 Wall lead through section view...
Страница 30: ...40ea manual 29 Measurements for the hole are 516x328mm...
Страница 32: ...40ea manual 31 Heater fuel connections Suitable fuels Wallas Marin recommends to use 100 HVO Diesels...
Страница 37: ...40ea manual 36 2 Connect drill pump to the free end of t branch and close one line with hose pinching pliers...
Страница 39: ...40ea manual 38 5 Unplug the drill pump s hose and plug T branch...