background image

40ea manual

- 40 -

Wallas - 40EA

Wallas-Marin Oy

Kärrykatu 4

20780 Kaarina

Finland

http://www.wallas.com/

Oikeudet muutoksiin pidätetään.
Vi behåller rätten att göra ändringar.
We reserve the right to changes.
Änderungen vorbehalten.
Nous nous réservons le droit de faire des changements.
Wij behouden ons het recht voor deze te wijzigen.
Ci riserviamo il diritto di apportare modifiche.
Vi reserverer oss retten til endringer.

Document number: 490608

Содержание 40ea

Страница 1: ...ions of the device 9 9 Installation Remote control 4431 14 14 Control panel Classic Operations 22 22 Safety distances Safety distances 24 24 Installation Instructions for wall lead through installatio...

Страница 2: ...40ea manual 1 Technical information Fuel HVO B7 B10 XTL oils Operating voltage 12V DC Consumption 0 16 0 4 l h Heating power 1600 4000 W...

Страница 3: ...ory Power consumption 0 2 0 4 A when ignited ca 4 5 min 8 A Measurements 730x440x240 mm Weight ca 25 0 kg Max permissible length of the flue gas pipe 3 m 6 m insulated Max permissible length of the fu...

Страница 4: ...40ea manual 3 Conformity with ecodirective Wallas 40EA conforms with ecodirective...

Страница 5: ...automatically The heat sensor in the heater detects the flame s heat and lights the red LED to signal that the device has started All functions are controlled electronically The fuel pump and combusti...

Страница 6: ...onnections easy to open and disconnect The device does not need to be detached to clean the burner The heater should be installed on the level The inclination must not exceed 5 While the device should...

Страница 7: ...e of the system 0 5 bar To prevent corrosion the hot water system has to contain enough antifreeze coolant liquid following the manufacturers recommendations To prevent freezing hot water system has t...

Страница 8: ...e system like in this example the heating mat with additional pump can be in another room than others so when additional pump is on more heat goes through boiler and the mat with additional pump When...

Страница 9: ...cs Exhaust head 4004 2 pcs Covering plate 360x360 8 pcs Fastening screw 4 5x15 4 pcs Fastening screw 4 5x25 Mounting kit 4880 0 5 m Exhaust pipe 4845 0 5 m Insulating channel 4012 2 pcs Insulation man...

Страница 10: ...ctly under normal operating conditions Insulate unused cable ends The device uses 12 V nominal direct current voltage To minimize current losses make the power cable as short as possible and avoid joi...

Страница 11: ...40ea manual 10 Electrical connections of the device...

Страница 12: ...40ea manual 11...

Страница 13: ...40ea manual 12...

Страница 14: ...fore connecting the device Without the battery the voltage reducer will not be enough on its own as it cannot generate the large amount of current the glow plug requires After the 12 V battery the con...

Страница 15: ...llation of device Remote control 4431 Introduction The remote starter 4430 The remote starter is intended for communicating data through a GPRS network The unit is intended for remote controlling of h...

Страница 16: ...e LED lights of the remote starter Green light means good signal red lights means poor signal and if there is no signal the light is off The LED light flashes once every ca 7 seconds If a text command...

Страница 17: ...On web page remote wallas fi check that the SIM card operator is included in the tested operator list 3 Check that the PIN code request of the SIM card is disabled If necessary disable it 4 Install th...

Страница 18: ...s for the ON OFF function The setting can vary but they are explained in this section Note that one text message can contain a combination of several commands General preconditions for sending a text...

Страница 19: ...40ea manual 18 Turn the heater of by sending 1234 R10...

Страница 20: ...o update the S4 data Therefore it is recommended that the ON OFF OFF TEMPERATURE com mands are sent separately with an interval of at least 15 seconds S status This command provides an overview of the...

Страница 21: ...accumulator charge Check the GSM signal Check the aerial connection The green LED flashes with short intervals Check whether the SIM card is in place Check if the PIN code has been disabled Check whe...

Страница 22: ...40ea manual 21 Connect the unit to the power source and keep the button down for at least 10 seconds Release the button The factory settings have now been restored The unit is now ready for use...

Страница 23: ...bustion indication led s Blinking logic No error Init Off LED off CoolDown PauseCoolDown Rampdown PauseRampDown LED blinking slowly 1 0 s on 1 0 s off Pause mode LED blinking gently and smoothly like...

Страница 24: ...lid reading 4 blinks Other temperature sensor Air temp sensor invalid reading missing Water temp sensor invalid reading missing Room temp sensor invalid reading missing 5 blinks Ventilation fan Missin...

Страница 25: ...device so that the space can be kept clean and free of dust litter and other unwanted objects The openings for the air intake in the lower section of the device s casing must be unobstructed There mu...

Страница 26: ...found in the heater accessory bag The exhaust pipe cannot be tightened sufficiently by any other fastening than a pipe clamp 11 which must be tightened sufficiently to lock the pipe in place 14 Place...

Страница 27: ...40ea manual 26 Wall lead through section view...

Страница 28: ...The device is ready for use after you connect the power cord and the fuel hose Note If you choose to lead in the combustion air from under the floor ensure there is sufficient ventilation in the foun...

Страница 29: ...8 Teg installation Teg element is attatched to heaters exhaust and it converts the exhaust heat to electricity and it load s the systems batteries when heater is on Teg is flush mounted to a wall behi...

Страница 30: ...40ea manual 29 Measurements for the hole are 516x328mm...

Страница 31: ...40ea manual 30 Electrical connections Heater mains are connected to a load connectors battery is connected to batt...

Страница 32: ...40ea manual 31 Heater fuel connections Suitable fuels Wallas Marin recommends to use 100 HVO Diesels...

Страница 33: ...e material for the fuel hose pipe the fuel filter and the hose clamps The inner diameter of a new replacement hose must be equal to the inner diameter of the plastic hose Copper pipe and metal filters...

Страница 34: ...2 The fuel tank can be placed in the base housing 4031 or outside it for exam ple in the foundations of the house or a suitable protective box Protect the tank and the fuel hose from direct sunlight...

Страница 35: ...0 x 300 x 130 mm 2024 Accessory 10 l 380 x 195 x 210 mm 2027 Accessory 33 l 500 x 235 x 355 mm 4030 Accessory 130 l 800 x 400 x 600 mm 4130 Accessory The fuel connections must be tightened firmly so a...

Страница 36: ...there will be airlocks Filling from the lowest point takes most of the air out from the system so this makes bleeding much easier If there is air in the ducting heater does not work correctly Premix e...

Страница 37: ...40ea manual 36 2 Connect drill pump to the free end of t branch and close one line with hose pinching pliers...

Страница 38: ...40ea manual 37 3 Pump coolant through the drill pump untill header tank starts filling 4 Relocate pinching pliers to the another line and start pumping coolant until it reaches the header tank...

Страница 39: ...40ea manual 38 5 Unplug the drill pump s hose and plug T branch...

Страница 40: ...for warranty service description of the problem a description of where and how the device was installed photographs of the installation may help product type and serial number place and date of purcha...

Страница 41: ...n pid tet n Vi beh ller r tten att g ra ndringar We reserve the right to changes nderungen vorbehalten Nous nous r servons le droit de faire des changements Wij behouden ons het recht voor deze te wij...

Отзывы: