![background image](http://html1.mh-extra.com/html/wallas/40ea/40ea_manual_3234513018.webp)
40ea manual
- 17 -
6. Install and connect the aerial
7. Switch of the heater’s main power
8. Ensure that the green LED light starts flashing with 7 sec intervals
Remote control by text messages
The 4430 unit can be controlled remotely by sending text messages to the unit.
This can be done by a normal GSM phone.
The unit has a number of commands for guiding the process. Each command is different and contains a letter, which
assigns a property to the text message. In addition to letters, numbers 1 and 0 are used as abbreviations for the
ON/OFF function.
The setting can vary, but they are explained in this section.
Note that one text message can contain a combination of several commands.
General preconditions for sending a text message:
• Use the GSM phone and write your text message.
• Start the text message with the default code 1234, and then write the command.
• Send the message to the telephone number assigned to the SIM card of the 4430 unit.
Controls
S Status message.
R Wallas heater control.
NOTE:
Spaces are permitted between commands, but PROHIBITED in the middle of a command.
“1234 W1 S4” is CORRECT, “1234 W 1 S 4“ is INCORRECT.
Control commands
Text message commands
“R1” – Wallas heater control
S4 Status command
Turn the heater on by sending:
"1234 R11"
Содержание 40ea
Страница 4: ...40ea manual 3 Conformity with ecodirective Wallas 40EA conforms with ecodirective...
Страница 11: ...40ea manual 10 Electrical connections of the device...
Страница 12: ...40ea manual 11...
Страница 13: ...40ea manual 12...
Страница 19: ...40ea manual 18 Turn the heater of by sending 1234 R10...
Страница 27: ...40ea manual 26 Wall lead through section view...
Страница 30: ...40ea manual 29 Measurements for the hole are 516x328mm...
Страница 32: ...40ea manual 31 Heater fuel connections Suitable fuels Wallas Marin recommends to use 100 HVO Diesels...
Страница 37: ...40ea manual 36 2 Connect drill pump to the free end of t branch and close one line with hose pinching pliers...
Страница 39: ...40ea manual 38 5 Unplug the drill pump s hose and plug T branch...