12 V direct current system
Connect the red wire of the power cord to the plus terminal of the battery and the black or blue wire to the minus
terminal. A 15 A main fuse must be installed near the battery on the red plus wire of the power cord. See picture.
24 V direct current system
If the device is to receive power from a 24 V system, always connect a charging voltage reducer and a 12 V battery
before connecting the device. Without the battery the voltage reducer will not be enough on its own as it cannot
generate the large amount of current the glow plug requires. After the 12 V battery, the connection is the same as in a
12 V system.
Checking the connection
The device consumes most power when it is started up (glowing). At this point voltage losses are also at their highest.
During the glowing phase, the voltage must be at least 9,5 V measured at the quick coupling. If the voltage is lower
than this, the device may not start.
All wires needs to be mounted with smooth bending and equipped with strain relief.
Содержание 40ea
Страница 4: ...40ea manual 3 Conformity with ecodirective Wallas 40EA conforms with ecodirective...
Страница 11: ...40ea manual 10 Electrical connections of the device...
Страница 12: ...40ea manual 11...
Страница 13: ...40ea manual 12...
Страница 19: ...40ea manual 18 Turn the heater of by sending 1234 R10...
Страница 27: ...40ea manual 26 Wall lead through section view...
Страница 30: ...40ea manual 29 Measurements for the hole are 516x328mm...
Страница 32: ...40ea manual 31 Heater fuel connections Suitable fuels Wallas Marin recommends to use 100 HVO Diesels...
Страница 37: ...40ea manual 36 2 Connect drill pump to the free end of t branch and close one line with hose pinching pliers...
Страница 39: ...40ea manual 38 5 Unplug the drill pump s hose and plug T branch...