JPA, JPC, JPD PT

Pumps and boosters

Installation and operating instructions

GRUNDFOS 

INSTRUCTIONS

Summary of Contents for JPA 12-41

Page 1: ...JPA JPC JPD PT Pumps and boosters Installation and operating instructions GRUNDFOS INSTRUCTIONS...

Page 2: ...ration must comply with local regulations and accepted codes of good practice This appliance can be used by children aged from 8 years and above and by persons with reduced physical sensory or mental...

Page 3: ...le to the liquid to be pumped 2 2 1 Frost protection If the pump is not used during periods of frost it must be drained to avoid damage Remove the drain plug to drain the pump See fig 3 Fig 3 Draining...

Page 4: ...ong horizontal stretches we recommend that you use an inlet pipe with a diameter larger than the inlet opening of the pump Fig 5 Inlet pipe sloping upwards 2 3 3 JPD deep well installation A JPD must...

Page 5: ...onnected to the protective earth of the pump The plug must therefore have the same PE connection system as that of the socket outlet If not use a suitable adapter We recommend that you fit the permane...

Page 6: ...r serious personal injury Do not use the pump for flammable liquids such as diesel oil petrol or similar liquids CAUTION Impurities in water Minor or moderate personal injury Flush the system with cle...

Page 7: ...e number of starts and stops an external tank can be installed JPA PT and JPC PT are boosters consisting of a pump a pressure switch a pressure gauge and a diaphragm tank The pressure switch automatic...

Page 8: ...1 17 16 15 14 13 2 3 4 5 6 7 8 12 11 10 9 3 1 TM06 7713 4016 Pos Description 1 Pump type 2 Product number 3 Full load current 4 Factory and production date 5 Motor input power 6 Pump output power 7 M...

Page 9: ...ts are available for the JPA JPC JPD pumps and boosters The service kits consist of the following replaceable parts shaft seal hydraulic parts capacitor DANGER Electric shock Death or serious personal...

Page 10: ...ies Clean the pump Check or replace the strainer in the inlet pipe d The suction lift is too high JPA JPC Maximum 7 m JPD Maximum 27 m Change the position of the pump e The inlet pipe is too long Chan...

Page 11: ...48 5 JPD 4 47 PT 4 JPD 4 54 PT 4 JPD 5 61 PT 5 JPD 8 62 PT 8 Pump type m JPA 3 42 JPA 3 42 PT H 42 JPA 4 47 JPA 4 47 PT H JPA 4 47 PT V 47 JPA 4 54 JPA 4 54 PT H JPA 4 54 PT V 54 JPA 5 61 JPA 5 61 PT...

Page 12: ...ate waste collection service 2 If this is not possible contact the nearest Grundfos company or service workshop See also end of life information on www grundfos com The crossed out wheelie bin symbol...

Page 13: ...13...

Page 14: ...1 51 E mail info_GDK grundfos com www grundfos com DK Estonia GRUNDFOS Pumps Eesti O Peterburi tee 92G 11415 Tallinn Tel 372 606 1690 Fax 372 606 1691 Finland OY GRUNDFOS Pumput AB Trukkikuja 1 FI 013...

Page 15: ...ona 421 2 5020 1426 sk grundfos com Slovenia GRUNDFOS LJUBLJANA d o o Lesko kova 9e 1122 Ljubljana Phone 386 0 1 568 06 10 Telefax 386 0 1 568 06 19 E mail tehnika si grundfos com South Africa Grundfo...

Page 16: ...450 Trademarks displayed in this material including but not limited to Grundfos the Grundfos logo and be think innovate are registered trademarks owned by The Grundfos Group All rights reserved 2019 G...