40ea manual
- 27 -
Instructions for attachment to the flue
Accessory 4880 is required for the installation.
1. Cut the flue-gas pipe, the insulation channel and the cover sheet metal to a length at which they extend to the inner
surface of the flue.
2. Fasten the hoses to the heater with clamps. The flue-gas pipe must be tightened firmly with a pipe clamp.
3. Put the heater in place, and fasten it to the floor or the base housing.
4. Insulate the joint between the flue-gas hose and flue with acrylic compound.
5. The device is ready for use after you connect the power cord and the fuel hose.
Note!
If you choose to lead in the combustion air from under the floor, ensure there is sufficient ventilation in the foundations
beneath the floor. Install the protective spiral on the end of the hose.
In a tall (over 5 m) flue, with a large cross-sectional surface (over 15x15 cm), the temperature of the flue-gases
decrease so much that the moisture in them condenses, resulting in funnel corrosion and a weakened air flow. Due to
this, a brick flue should be cased with a stainless steel pipe (diameter: 50-70 mm) and the gap between the pipe and
the flue filled, for example, with LECA.
Combustion air must not be taken from the flue.
Содержание 40ea
Страница 4: ...40ea manual 3 Conformity with ecodirective Wallas 40EA conforms with ecodirective...
Страница 11: ...40ea manual 10 Electrical connections of the device...
Страница 12: ...40ea manual 11...
Страница 13: ...40ea manual 12...
Страница 19: ...40ea manual 18 Turn the heater of by sending 1234 R10...
Страница 27: ...40ea manual 26 Wall lead through section view...
Страница 30: ...40ea manual 29 Measurements for the hole are 516x328mm...
Страница 32: ...40ea manual 31 Heater fuel connections Suitable fuels Wallas Marin recommends to use 100 HVO Diesels...
Страница 37: ...40ea manual 36 2 Connect drill pump to the free end of t branch and close one line with hose pinching pliers...
Страница 39: ...40ea manual 38 5 Unplug the drill pump s hose and plug T branch...