PRELIMINARY TESTING
Table 6. SmartDC Controller Board Inputs
Terminal
No�
Input Name
Pre-2016 Models
Wire Connections
Uses
17
Block Exit
Block Free Exit Vehicle
Detector or Close
Timer
N.O. input.
Free Exit is only disabled
if Close Limit Switch is
tripped. If the gate is
partially opened, the Free
Exit detector will trigger the
gate to open fully. The input
can be converted in the
Installer Menu (menu item
DT) to alternately disable
the Close Timer.
18
Inside
Obstruction
Loop
Inside Obstruction
Vehicle Detector
N.O. input.
Inside reversing loop.
Optional settings available:
Installer Menu item IR.
19
Outside
Obstruction
Loop
Outside Obstruction
Vehicle Detector
N.O. input.
Outside reversing loop.
Optional settings available:
Installer Menu item OR.
20
Center Loop
Center Loop (Shadow)
Vehicle Detector
N.O. input.
Shadow function used for
Swing gates only.
21
Sensor 1
Edge Sensor
N.C. input.
Type of sensor
used is programmable
in Installer Menu (S1).
External Entrapment Sensor
22
Sensor COM
Photo Eye Common
+24 Volts Common
All devices used for external
entrapment protection that
require monitoring must be
connected to SENSOR COM.
Device common power.
Connect external
entrapment protection
sensors to these terminals.
23
+24V
+24VDC
Convenient 24VDC power.
Convenient 24VDC power
for photo eyes or the
Emergency Open input.
24
Emergency
Open (Fire
Dept. Open)
***
Emergency Open (Fire
Dept. Open)
N.O. input.
The Emergency Open must
be enabled via the Installer
Menu. It is energized by
connecting to the +24V
terminal above it. The
EMERG OPEN overrides
photo eye & edge sensor
commands.
*Do not connect an external control to the STOP or OPEN inputs unless the controls are located in clear view of
the entire gate area.
**Use the RADIO OPEN input or RADIO OPTIONS spade connections for all out-of-sight controls, such as a telephone
entry or radio operated controls.
***The Fire Department Open control must be keyed or guarded so that it can only be used by authorized
personnel.
Содержание FOLDSMART
Страница 35: ...FoldSmart Installation and Maintenance Manual Revision 1 MAY 2023 35 FOLDSMART GATE INSTALLATION ...
Страница 36: ...36 wallaceperimetersecurity com Phone 866 300 1110 FOLDSMART GATE INSTALLATION ...
Страница 37: ...FoldSmart Installation and Maintenance Manual Revision 1 MAY 2023 37 FOLDSMART GATE INSTALLATION ...
Страница 38: ...38 wallaceperimetersecurity com Phone 866 300 1110 FOLDSMART GATE INSTALLATION ...
Страница 146: ......
Страница 147: ...FoldSmart XT Drawings Generic Site Layout and Options ...
Страница 148: ......
Страница 149: ......
Страница 150: ......
Страница 151: ......
Страница 152: ......
Страница 153: ......
Страница 154: ......
Страница 155: ......
Страница 156: ......
Страница 157: ......
Страница 158: ......
Страница 160: ......
Страница 162: ...115 Lowson Crescent Winnipeg Manitoba Canada R3P 1A6 Phone 866 300 1110 wallaceperimetersecurity com ...