POWER REQUIREMENTS
Power Requirements
When installing a dual-operator system, the following must be adhered to:
•
An electrical conduit for interconnecting wires must span between the two operators. The primary
-
secondary communication wires and any low voltage control wires must be installed in a conduit
that is separate from the high voltage power wires. Refer to
“Figure 18. Primary and Secondary
.
•
Complete the installation of both operators as separate machines and verify that their basic functions
are correct as solo operators before interconnecting them.
•
External control inputs, vehicle detectors and entrapment protection sensors may be connected to
either gate operator without regard to preference.
•
Be sure both operators are running the same software version. The software version is available on
the display by pressing the RESET button on the operator
.
The software version appears beneath
the word HYSECURITY
.
Keep the most current software loaded. It is available at
. Make it part of your maintenance routine to check for software upgrades on a regular basis.
•
Both operators can be connected to the same 20A circuit breaker in the main panel. The wire size
affects operator performance. Use the following chart as a guideline to size wire for the given
distance from the power source to BOTH operators.
AC Power - Dual Operators 14-gauge wire
12-gauge wire
10-gauge wire
115V
305 ft (95 meters)
500 ft (150 meters)
775 ft (240 meters)
230V
1220 ft (370 meters)
1950 ft (590 meters)
3100 ft (940 meters)
Table 9. Wire Length Chart
Содержание FOLDSMART
Страница 35: ...FoldSmart Installation and Maintenance Manual Revision 1 MAY 2023 35 FOLDSMART GATE INSTALLATION ...
Страница 36: ...36 wallaceperimetersecurity com Phone 866 300 1110 FOLDSMART GATE INSTALLATION ...
Страница 37: ...FoldSmart Installation and Maintenance Manual Revision 1 MAY 2023 37 FOLDSMART GATE INSTALLATION ...
Страница 38: ...38 wallaceperimetersecurity com Phone 866 300 1110 FOLDSMART GATE INSTALLATION ...
Страница 146: ......
Страница 147: ...FoldSmart XT Drawings Generic Site Layout and Options ...
Страница 148: ......
Страница 149: ......
Страница 150: ......
Страница 151: ......
Страница 152: ......
Страница 153: ......
Страница 154: ......
Страница 155: ......
Страница 156: ......
Страница 157: ......
Страница 158: ......
Страница 160: ......
Страница 162: ...115 Lowson Crescent Winnipeg Manitoba Canada R3P 1A6 Phone 866 300 1110 wallaceperimetersecurity com ...