![Wallace Perimeter Security FOLDSMART Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/wallace-perimeter-security/foldsmart/foldsmart_installation-and-maintenance-manual_3222977030.webp)
30
wallaceperimetersecurity.com
Phone: 866.300.1110
FOLDSMART GATE INSTALLATION
2.
Using a leveling device, check to see that the foundations for the gate are level with each other. In case
of foundations that have been set to different elevations, the anchor bolts will need to be lengthened
to accommodate the inconsistency.
FoldSmart Gate columns should always be placed as close as
possible to the concrete foundation, using leveling nuts in all cases.
3.
Place each steel anchor bolt template on the prepared foundations making sure that templates are
aligned and centered on the foundations. If the FoldSmart Gate is being installed near a wall, object
or pre-existing opening make sure that each side of the template is the same distance from the wall,
object or pre-existing opening. See FoldSmart site-specific general layout drawings that are provided
by Wallace Perimeter Security for exact dimensions of the gate foundations.
4. Ensure that the required conduits fit in the center of the anchor bolt template. Using 3/4” anchor bolts
[.75” (19mm) HILTI HAS 5.8 x 14” (356mm) or equivalent], imbed the anchors using epoxy chemical
anchor (HILTI HVU2 or approved equivalent).
The
manufacturer’s
written
instructions must be read and followed
prior to using the epoxy system.
5.
Ensure minimum of 5-3/4” (14.6cm) thread is exposed above the foundation, and 8-1/4” (21cm)
embedment minimum. See chemical anchor installation guide accompanying the product for depth
of anchor holes. HILTI anchors and epoxy are available from Wallace Perimeter Security.
The installer shall read and follow the manufacturer’s written instructions for HILTI HVU2 3/4” X 8 1/4”
accompanying the shipped adhesive capsule product. Refer to step-by-step diagram on the following
pages, summarized below.
Anchor Bolt Template and Foundation
Содержание FOLDSMART
Страница 35: ...FoldSmart Installation and Maintenance Manual Revision 1 MAY 2023 35 FOLDSMART GATE INSTALLATION ...
Страница 36: ...36 wallaceperimetersecurity com Phone 866 300 1110 FOLDSMART GATE INSTALLATION ...
Страница 37: ...FoldSmart Installation and Maintenance Manual Revision 1 MAY 2023 37 FOLDSMART GATE INSTALLATION ...
Страница 38: ...38 wallaceperimetersecurity com Phone 866 300 1110 FOLDSMART GATE INSTALLATION ...
Страница 146: ......
Страница 147: ...FoldSmart XT Drawings Generic Site Layout and Options ...
Страница 148: ......
Страница 149: ......
Страница 150: ......
Страница 151: ......
Страница 152: ......
Страница 153: ......
Страница 154: ......
Страница 155: ......
Страница 156: ......
Страница 157: ......
Страница 158: ......
Страница 160: ......
Страница 162: ...115 Lowson Crescent Winnipeg Manitoba Canada R3P 1A6 Phone 866 300 1110 wallaceperimetersecurity com ...