2789-9023
Fieldbus Description
42
Product manual | Version: 1.0.0
EtherNet/IP Communication Module
No.
Description
JSON Format
2
Output voltage
"Voltage" : {
"Value" : "
value
",
"Unit" : "mV" }
3
Output current
"Current" : {
"Value" : "
value
",
"Unit" : "mA" }
4
Status
"Device Status" : {
"Status DC O.K." : "
value
",
"Status overheating" : "
value
",
"No output voltage" : "
value
",
"Output short circuit" : "
value
",
"Status of digital input" : "
value
" }
5
Warnings
"Warnings" : {
"Output under-voltage" : "
value
",
"Output over-voltage" : "
value
",
"Overload" : "
value
",
"Adjustable output current limit exceeded" : "
value
",
"Adjustable operating hour limit exceeded" : "
value
",
"Top boost supplied" : "
value
",
"Power Boost supplied" : "
value
",
"High device temperature" : "
value
",
"Digital input active" : "
value
" }
6
Errors
"Errors" : {
"Overheating, device switched off" : "
value
",
"No output voltage" : "
value
",
"Output short circuit" : "
value
",
"Electronic circuit breaker tripped" : "
value
" }
7
Control word
"Output" : {
"Device standby" : "
value
"
1)
,
"Digital out on" : "
value
" }
1 Not yet supported by the WAGO Pro 2 Power Supply
The following process data can be written in JSON format (communication module “
Sub-
scribe
” from the broker):
Table 52: Writing Process Data in JSON Format
No.
Description
JSON Format
1
Control word
"Output" : {
"Device standby" : "
value
",
1)
"Digital out on" : "
value
" }
1 Not yet supported by the WAGO Pro 2 Power Supply