30
VM 500
OPERATING MANUAL
EDITION 07/2014
ORDER NUMBER DOC2344502
10
PRODUCT DISPOSAL
9
MAINTENANCE AND REPAIR
9.1
MAINTENANCE
9.2
REPAIR
The functionality and completeness of the control unit have to be checked regularly. All
sealed elements on the control unit must be present and undamaged. During operation,
all electric connections of the control unit have to be tightly sealed with the corresponding
plug connectors or closing elements.
The leakage tightness of the device has to be checked at least every 3 years. The "Restricted
breathing" requirements according to DIN EN 60079-15:2011 have to be fulfi lled. This
inspection may only be carried out by an authorized person or by trained Wagner Service
Personnel. When carrying out the leakage tightness test, the mains input terminal serves
as a test port.
Repairs to the control unit may only be carried out by trained Wagner Service personnel.
This also includes opening the control unit.
After repair has been completed, the control unit has to be checked for leaks. The "Restricted
breathing" requirements according to DIN EN 60079-15:2011 have to be fulfi lled. When
carrying out the leakage tightness test, the mains input terminal serves as a test port.
Do not dispose of used electrical equipment with household
refuse!
In accordance with European Directive 2002/96/EC on the disposal
of used electrical equipment and its implementation in national
law, this product may not be disposed of with the household refuse,
but must be recycled in an environmentally correct manner.
Wagner or one of our dealers will take back your used Wagner
electric or electronic equipment and will dispose of it for you in
an environmentally-friendly way. Please contact one of our service
points, one of our representatives or us directly to arrange this.
NOTICE
Sparks form when live components are separated or connected!
Explosion hazard from electric sparks.
Do not disconnect plug connections under voltage.
Do not open fuse holders under voltage.
Do not remove the service plug cover under voltage.
WARNING