The following points should be noted before commissioning:
Lay grounding cable from the grounding screw on the device to the signal ground
and ensure that all other conductive parts within the working area are grounded.
Connect the VM 500 electrostatic control unit via the mains cable to the socket
interlocked with the extraction system.
Connect the gun cable to the connector socket and screw into place.
Connect the gun to the adjustable, clean air supply.
Compressed air quality class 3.5.2 according to ISO 8573.1.
Connect the GM 5000EA or GM 5000EAC to the paint supply as described in the relevant
operating manuals.
Check that all product-conveying connections are correctly connected.
Check that all air-conveying connections are correctly connected.
Visually check the permissible pressures for all the system components.
Check the level of the separating agent in the pump and fi ll up if necessary.
Provide product tank, tanks for fl ushing agent and an empty tank for return fl ow.
The interface input on the back of the control unit has to be protected by the cover.
Connect the system to the air supply.
When fi rst commissioning the unit -> Clean the system in accordance with the
operating manuals for the other components.