5
PC 1030
Mortar hose
Danger of injury through leaking high-
pressure hose. Wear and tear and links as
well as usage that is not appropriate to the
purpose of the device can cause leakages
to form in the mortar hose. Liquid can be
injected into the skin through a leakage.
Mortar hoses must be checked thoroughly before they are
used.
Replace any damaged mortar hose immediately.
Never repair defective mortar hoses yourself!
Avoid sharp bends and folds: the smallest bending radius is
about 80 cm.
Do not drive over the mortar hose. Protect against sharp ob-
jects and edges.
Never pull on the mortar hose to move the device.
Do not twist the mortar hose.
Lay the mortar hose in such a way as to ensure that it cannot
be tripped over.
Only use WAGNER original-mortar hoses in
order to ensure functionality, safety and du-
rability.
The risk of damage rises with the age of the
mortar hose.
Wagner recommends replacing mortar hoses
after 6 years.