Introduction PEM-CG3
1. Safety
regulations
Warning
This equipment can be dangerous if it is not operated in accordance with this
operating manual!
There might be additional regulations to be observed, put into effect by
governmental, state or other official agencies or local security (fire)
departments!
The following rules must be observed in order to ensure a safe and efficient use of the
equipment:
•
Under no circumstance may persons with a
cardiac pacemaker come close to the area
between the tip of the spray gun and the
workpiece to be coated!
•
The user has to observe particularly the safety
guidelines of the VdS or the local professional
and security institutions.
•
The spray gun may only be operated in powder
coating booths or on powder coating stands that
are equipped with a ventilation system.
•
The user has to make sure, that the average
powder/air concentration does not exceed 50%
of the LEL (maximum allowed concentration of
powder in air). If a reliable LEL value is not
available, the average powder/air concentration
may not exceed 10 g/m³.
•
The main power connection for operation of the
Wagner powder equipment
must
be electrically
interlocked with the exhaust system of the
powder coating booth.
•
In the event of faults or defects, repair work is to
be performed at the user's discretion.
•
Specially trained personnel may only carry out
repairs.
•
Repairs must never be performed in an
explosion-hazard area.
•
The work area
must
have an electrostatically
conductive floor (measured in accordance with
EN 1081).
•
All conductive parts in the work area
must
be
electrostatically grounded (work area = 1 m
around every spray location or opening in the
booth).
•
All persons inside the work area
must
wear
electrostatically conductive footwear.
•
Gloves are not to be worn! If gloves are used
they
must
be made of conductive material.
Also refer to chapter
Applicable safety regulations and list of sources
General Safety Rules
•
Wear suitable work clothing
•
Use breathing protection for work which
produces powder
•
Check your equipment for damage
Before using the system, carefully inspect
slightly worn parts for proper operation.
Check whether the moving parts operate
properly, whether they jam and whether parts
are damaged.
Damaged parts should be repaired or replaced
by a Wagner customer service.
Warning
For your own safety, use only accessories and equipment listed in the
operating manual. The use of individual parts other than those
recommended in the operating manual may create a hazard to personal safety.
Use only original Wagner replacement parts!
Alteration or repair of Wagner original spare parts may cause fatal accidents or
explosions in the coating system!
03/2003 5 0351713
Содержание PEM-CG3
Страница 23: ......