Start up and Working
PEM-CG3
3.3
Performing a color change
During a color change all parts carrying powder
must
be
thoroughly
cleaned of powder
residue.
1
2
3
5
4
•
Switch off the high voltage generator at the
control unit.
•
Unscrew the powder container
H
from the
adapter
J
.
•
Close the fluid air supply with the
green
setting knob
L
.
•
Open the feed air supply wide with the
red
setting knob
K
.
•
Hold the manual spray gun in the spray
booth, actuate the trigger, so that the spray
gun is blown free of powder.
•
Switch off the control unit and secure it
against inadvertent switching on.
•
Pull the deflector cone
1
off the nozzle
insert
3
.
•
Unscrew the outer nut
2
from the spray gun
housing
4
.
•
Carefully pull the nozzle insert
3
out of the
spray gun housing
4
.
Caution
When pulling out and inserting the nozzle insert, ensure that the insert is not damaged!
•
Remove powder residue from the parts removed, from the spray gun and the powder
container.
•
Mount the cleaned or a new powder container
H
.
Hint
An individual powder container can be used for each color.
•
Prior to re-fitting, check whether the mating faces on the nozzle insert
3
and in the spray
gun housing
4
have been thoroughly cleaned so that the electrode tip is electrically
connected to the high voltage generator.
•
Carefully refit the nozzle insert
3
in the spray gun housing
4
and tighten using the outer
nut 2.
•
Slide the deflector cone back over the nozzle insert.
The spray gun is ready for use again and you may begin with the setting of the spray pattern
in accordance with chapter
.
03/2003 11 0351713