Start up and Working
PEM-CG3
2.3
Connecting the spray gun
•
Connect the spray gun to the control
unit with the electrical cable.
•
Connect the black hose (external
∅
6x2) for the air supply to the spray
gun.
•
The reducer (6/8) should be inserted
into the other end of the hose and this
in turn attached to the feed air
connection on the control unit when
connecting the gun to the
EPG 2007
control unit
.
Air supply from the control unit
to the electrical connection at the control unit
2.4 Grounding
In order to achieve a good powder coating, proper grounding for the
workpiece
is absolutely
essential. A poorly grounded workpiece causes:
•
dangerous electric charging of the workpiece
•
back-spray onto spray gun and user
•
very bad wrap-around
•
uneven coating
Warning
Sparks between workpiece and conveyor hooks (hangers) can occur if hooks or
other hanger parts are not completely cleaned!
These sparks can cause heavy radio frequency interference.