Grounding scheme (example)
B_00304
R max < 1 M
Ω
Product
tank
Work piece
Conveyor
Spraying stand
Floor, static dissipative
Ex zone
Part / workstation
Cable cross section
Pump
4 mm2; AWG 12
Product tank
6 mm2; AWG 10
Conveyor
16 mm2; AWG 6
Booth
16 mm2; AWG 6
Spraying stand
16 mm2; AWG 6
Safe operation of the IceBreaker pump is only guaranteed with a grounding
connection. Connect all grounding cables using a short and direct route.
B_05443
Procedure:
1. Screw on grounding cable with eyelet.
2. Clamp the grounding cable clip to a grounding connection on site.
3. Ground the product tank to an on-site grounding connection.
4. Ground the other parts of the system to an on-site grounding
connection (16 mm2; AWG 6).
Ex zone
All devices and equipment must be suitable for use in potentially explosive areas.
All paints, flushing agents and waste tanks have to be electrically conductive.
All tanks must be grounded.