![WAGNER Jaguar 75-150 Скачать руководство пользователя страница 23](http://html2.mh-extra.com/html/wagner/jaguar-75-150/jaguar-75-150_operating-manual_3176155023.webp)
23
VERSION 02/2018
ORDER NUMBER DOC 2340282
IceBreaker 150-300 cm
3
5.5.5 TECHNICAL DATA FOR TIGER
Pump ratio
72:1
Volume flow per double stroke ( )
cm3; cc
300
Maximum operating overpressure
MPa; bar; psi
53; 530; 7687
Maximum possible strokes in operation
/min.
40
Maximum recommended strokes per minute in
continuous operation
/min.
30
Minimum/maximum air inlet pressure
MPa; bar; psi
0.25–0.74; 2.5–7.4; 36–107
Compressed air quality: free from oil and water
Quality standard 7.5.4 according to ISO 8573.1, 2010
7: Particle concentration 5 – 10 mg/m³
5: Humidity: pressure dew point ≤ 7 °C
4: Oil content ≤ 5 mg/m3
Air inlet (inside thread)
inch
G 1"
Minimum Ø of the compressed air supply line
mm; inch
25; 1.0
Air consumption at 0.6 MPa; 6 bar; 87 psi per double
stroke
nl; scf
170; 6
Air motor piston diameter
mm; inch
300; 11.8
Air motor piston stroke
mm; inch
150; 5.9
Sound pressure level at maximum permissible air
pressure*
82
Sound pressure level at 0.6 MPa; 6 bar; 87 psi air
pressure*
80
Sound pressure level at 0.4 MPa; 4 bar; 58 psi air
pressure*
75
Product inlet (inside thread)
mm
G1 1/2"
Product outlet (outside thread)
mm
M24×1.5
Weight
kg; lb
80; 176
Product pH value
pH
3.5–9
Maximum product pressure at pump inlet
MPa; bar; psi
2; 20; 290
Product temperature
5–80; 41–176
Ambient temperature
Construction and
assembly
5–50; 41–122
Storage
-20–60; -4–140
Relative humidity
%
10–95 (without condensation)
Allowable inclination for operation
± 10
* A-rated sound pressure level measured at 1 m distance, L pA1m, according to DIN EN 14462: 2005.
Reference measurements have been made by SUVA (Swiss Accident Insurance Institute).
WARNING
Exhaust air containing oil!
Risk of poisoning if inhaled.
Provide compressed air free from oil and water.