Maintenance
LTN 6L
54
wc_tx000767gb.fm
6.3
Replacing / Removing Lamps
Prerequisites
•
Engine shut down
•
Light circuit breakers turned OFF
•
Lamps and fixtures cool to the touch
•
Eye protection and gloves
Follow the procedures below to remove and install the lamp.
Removing the lamp
6.3.1
Remove the screws
(a)
securing the flange rings
(b)
and remove the
flange rings.
WARNING
Burn hazard. Lamps become extremely hot in use.
f
Allow lamps and fixtures to cool 10–15 minutes before handling.
WARNING
Personal injury hazard. Ultraviolet radiation from the lamps can cause serious skin
and eye irritation.
f
Use only undamaged lamps.
f
Use the lamps only with undamaged original equipment lenses and fixtures.
WARNING
Explosion hazard. Grease or oil residue on the lamp can cause the outer jacket to
burst or shatter. Hot flying glass particles can cause personal injury, property dam-
age, burns, or fire.
f
Do not operate the lights with a lens that is cracked, damaged, or missing.
f
Do not scratch the lamp or subject the lamp to excess pressure.
f
Wear eye protection and gloves when removing or replacing lamps.
a
d
c
b
e
f
wc_gr005881